The ProControl 1KE Plus software allows for multiple control methods, which are selected and configured on
the Setup screens. The control method you chose will determine the information and options available on
the Run Screens.
Control methods are selected on
Setup Screen 13: Control Method, page 52
.
1.
The Control Method setup screen.
2.
Select the icon for your control method.
The control method options are described in the
following table.
Table
Table
Table 1
1
1 Control
Control
Control Methods
Methods
Methods and
and
and Run
Run
Run Screen
Screen
Screen Examples
Examples
Examples
Selection
Selection
Selection
Icon
Icon
Icon
Description
Description
Description and
and
and Typical
Typical
Typical Application
Application
Application
Run
Run
Run Screen
Screen
Screen Examples
Examples
Examples
Monitor
Monitor
Monitor and
and
and Accumulate
Accumulate
Accumulate Volume
Volume
Volume Only
Only
Only
No active control. The system drives to the setpoint
immediately, and will not adapt to changes in pressure or
flow.
ADCM
ADCM
ADCM Only
Only
Only
An ADCM that is not configured with specific pressure
sensors, flow meters, or output controls has limited
capabilities on the run screen. However, all of the system
setup screens are still available for offline configuration.
Closed
Closed
Closed---Loop
Loop
Loop Pressure
Pressure
Pressure Control
Control
Control
Drives to a fluid pressure target, and may monitor flow. The
system drives to the setpoint using the PID control. It will
not adapt to changes in flow.