Setup
Setup
Setup Screen
Screen
Screen 12:
12:
12: Flush
Flush
Flush Mode
Mode
Mode
Use this screen to set up the parameters for Flush
Mode. When set, the Minimum Flush Volume is
checked against the amount of material that flowed
during the Flush process. The “SP” Minimum Flush
Volume alarm is set if this isn’t achieved.
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Set fluid regulator to a percent open.
The first box displays the remaining
time when a Flush Mode is active.
Set a flush duration time.
Minimum Flush Volume. Set zero to
disable this feature
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.
Setup
Setup
Setup Screen
Screen
Screen 13:
13:
13: Control
Control
Control Method
Method
Method
Use this screen to set the system control method.
See
Control Method Considerations, page 32
, for
more information.
Table
Table
Table 14
14
14 Setup
Setup
Setup Screen
Screen
Screen 13
13
13
Description
Description
Description
Examples
Examples
Examples
With control
method
selected
With selection
menu open
Key
Key
Key
Enter the screen to set or change
preferences.
Press to activate a field for editing or
to accept the highlighted selection on
a menu.
Move to the right when editing number
fields. Press again to accept the entry
when all digits are correct.
Control Method selection.
Scaled percentage of the 4mA to 20mA
range of the control valve.
Direct pressure setpoint for closed-loop
control.
Direct flow rate setpoint for closed-loop
control.
Direct milliamp output selection to the
control valve.
Exit data editing.
Move between Setup Screens, fields
on a screen, or to increment/decrement
the digits when editing number fields.
52