Installation
3A1704N
3
Installation
1. Install the CGM in the desired location.
a. Remove access cover (D). Loosen two screws
(C) and remove CGM (A) from base (B).
b. Mount base (B) in desired location with four
screws supplied in this kit. See the following
mounting dimensions.
c. Mount CGM (A) on base (B) with two
screws (C).
2. Install access cover (D).
3. Attach the ferrite suppressor to the CGM on each
end of the CAN cable.
NOTE:
CAN ports are located on the base of cube
shaped GCA modules or port 6 on the High Power Tem-
perature Control Module.
NOTE:
If there are no free CAN ports, plug
splitter (121807) into the CAN distribution block located
in the Power Distribution Box (PDB). Connect the CAN
cable into the splitter. For more detail, refer to the CAN
Adapter Kit manual.
F
IG
. 1
D
A
C
B
3.25 in.
(82.6 mm)
2.75 in.
(69.9 mm)
#10-32 UNF
(M5 x 0.8)
NOTICE
To avoid severe damage to GCA modules, ensure
the CAN cable is connected to the appropriate CAN
connection.
NOTICE
To avoid severe machine damage, do not connect
any CAN device to connectors 2A, 2B, or 2C on the
Motor Control Module. Connectors 2A, 2B, and 2C
are not CAN connectors.
F
IG
. 2: Cable Connections
CAN
Connector 1
ti11972a
CAN
Connector 2