Available Internal Data
18
3A1704N
13
0
Units and Operating Information: Rate Unit
0
Minute
1
Second
1
Units and Operating Information: Control Mode
0
Pressure
1
Flow
2
Units and Operating Information: Dispense Mode
32 (bits)
00 = Time
01 = Volume
10 = Weight
3
4
Not Used
0
N/A
1
N/A
5
Not Used
0
N/A
1
N/A
6
Not Used
0
N/A
1
N/A
7
Not Used
0
N/A
1
N/A
14,
15,
16,
17
Double
Integer
Flow Rate Set point: Integer value of the Flow rate set point in the dispensing system
The value from the CGM is an integer and must be multiplied by 0.0001 for the requested
flow rate to be in system units.
Example: Double word 14 = 291234 = 29.1234cc/sec (unit chosen is cc/sec)
18,
19,
20,
21,
Double
Integer
Dispense Amount (Shot Size) Set point: Integer value of the Dispense amount set point in
the dispensing system.
The value from the CGM is an integer and must be multiplied by 0.001 for the requested
dispense amount to be in system units.
Example: Double word 18 = 5002499 = 5002.499cc (unit chosen is cc)
22,
23
Integer
Ratio Set point: Integer value of the Red / Blue Material Ratio set point in the dispensing
system. Note this value is dependent on the pump sizes and does not vary.
The value from the CGM is an integer and must be multiplied by 0.01 for the requested ratio
to be in system units. xx.xx: 1 where xx.xx is Red and 1 is Blue
Example: Word 22 = 2400 = 24.00:1 (red pump = 120, blue pump = 5)
24,
25,
26,
27
Double
Integer
Red Pump Pressure Actual: Integer value of the actual Red pump pressure.
The value from the CGM is an integer and must be multiplied by 0.0001 for the actual pres-
sure to be in system units.
Example: Double word 12345678 = 1234.5678psi (unit chosen is psi)
28,
29,
30,
31
Double
Integer
Blue Pump Pressure Actual: Integer value of the actual Blue pump pressure.
The value from the CGM is an integer and must be multiplied by 0.0001 for the actual pres-
sure to be in system units.
Example: Double word 7561234 = 756.1234psi (unit chosen is psi)
Byte
Bit
Data
Type