background image

Installation

3A0860J

3

Installation

The USP Valve should be ready to install in your sys-
tem. It has been factory-tested and should not require 
any additional modification.

As long as lubricant is supplied under pressure, the 
valve will continue to operate . Whenever lubricant flow 
ceases, the valve pistons stop. When flow resumes, it 
will start again at the same point in the discharge cycle.

NOTE:

 The manufacturers of the machine tool and its 

component bearings should be consulted to ensure that 
the ISO 18/14 cleanliness level is adequate.

Outlet Adapters

Each block ships with the correct number of outlet 
adapters and seals. Install one adapter into each open 
outlet port. Be sure a seal is installed on each outlet 
adapter.

Outlet adapters have standard threads for interfacing 
with tube fittings. 

Recommended Tube Fittings

Fittings should have a maximum 9/16 in. (14 mm) 
hex.

USP Divider Port Combination

USP divider block outlets can be combined to increase 
the amount of lubricant for a particular outlet. 

Option 1

1.

Remove the outlet adapter from block. 

2.

Remove face seal (a) from outlet adapter (b) (F

IG

1)

3.

Plug outlet adapter (b) with user supplied plug (c) to 
double the output volume.

Lubricant from the plugged outlet adapter is redirected 
to the next outlet on the USP divider block flowing in a 
clockwise order, following direction arrows (A) stamped 
on block (see F

IG

. 1).

For example in F

IG

. 1

: Removing face seals and plug-

ging 2 outlet adapters will triple the amount of lubricant 
at the next outlet. This outlet will include the output of 
plugged outlets that are now rerouted as well as it’s own 
output.

Option 2- Using Doubling Plug Accessory

1.

Remove the outlet adapter (b) and face seal (a) 
from outlet that is going to be combined (F

IG

. 2).

NOTICE

Supplied outlet adapters are required for full func-
tionality and testing.

F

IG

. 1

A

ti13744

a

b

c

3x output

F

IG

. 2

b

a

Summary of Contents for 24E406

Page 1: ...Working Pressure Models For all models Discharge per outlet 0 012 in 3 Important Safety Instructions Read all warnings and instructions in this manual Save these instructions Model No No of Outlets In...

Page 2: ...hoses and couplings daily Replace worn or damaged parts immediately EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury Do not operate the unit when fatigued or under the influence of dru...

Page 3: ...ings should have a maximum 9 16 in 14 mm hex USP Divider Port Combination USP divider block outlets can be combined to increase the amount of lubricant for a particular outlet Option 1 1 Remove the ou...

Page 4: ...rging Air From System Before machine operation is resumed following mainte nance or repair procedures manual system air purging is required Purging Air from Pump to USP Valve Lines Steps 1 3 refer to...

Page 5: ...at lubrication points 4 Disconnect and remove the line from the pump at the valve inlet 5 Attach a hand pump filled with clean filtered lubri cant to the inlet port 6 Operate the hand pump until air f...

Page 6: ...ll only tem porarily solve contamination blockage problems The source of the contamination must be eliminated for sat isfactory service The system filtering method must be investigated filter elements...

Page 7: ...4E409 1 VALVE 8 piston honed models 24E410 24E411 1 2 24E757 PLUG w o ring models 24E406 24E407 8 PLUG w o ring models 24E408 24E409 12 PLUG w o ring models 24E410 24E411 16 3 24E857 KIT checked outle...

Page 8: ...tch 200 cpm Mounting Holes Accommodate Bolt Diameter 0 25 in 6 mm USP Outlets Length Width Thickness Mounting Holes A Mounting Holes B inch mm inch mm inch mm inch mm inch mm 6 2 98 75 7 2 37 60 2 1 5...

Page 9: ...SP Valve models On the following diagrams the factory plugged outlets are represented as blacked ports Do not remove plugs from the factory plugged outlets 1 8 2 3 4 5 6 7 9 16 10 11 12 13 14 15 1 8 2...

Page 10: ...tion of the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WAR...