Setup
22
Learn Mode
Learn mode enables the shot controller to learn the
left-most and right-most piston positions. To do this, the
standard piston controls are disabled and the piston is
moved left and right using the top soft key. With Learn
mode enabled the top soft key icon will be a left or right
arrow to signify the direction the piston will move when
pressed. In the usual bottom soft key icon location, the
left-most and right-most piston positions obtained from
using Learn mode will be shown.
Learn Piston Left-most and Right-most
Positions
Enable Learn Mode
1.
Change the operating mode to Manual, see
section on page 27.
2.
Navigate to setup screen #8. See F
3.
Select the top soft key with the “Enter Learn Mode”
icon and confirm the selection when prompted. See
section on page 8.
4.
Press and hold both the top and bottom soft keys for
three seconds to exit the setup screens.
Obtain Piston Range Information
5.
Using a bucket to catch the dispensed material, trig-
ger the gun until the piston reaches the left-most or
right-most position.
6.
Manually reverse piston direction by pressing the
top soft key.
7.
Repeat steps 5 and 6 until the piston range dis-
played in the bottom right corner of the screen
remains constant.
Disable Learn Mode
8.
Navigate to setup screen #8.
9.
Press the soft key adjacent to the “Disable Learn
Mode” icon. Confirm the selection when prompted.
10. Exit setup mode by pressing and holding both soft
keys for three seconds.
Learn mode will need to be used following the
installation of the conversion kit, the linear sensor
or its mounting bracket, or the shot controller.
The IPH units are programmed at the factory so
Learn mode will not need to used prior to pouring.
F
IG
. 13: Run Screen with Learn Mode Enabled
To view the physical piston movement, remove the
front cover (CA) from the machine. Replace the
cover when finished using Learn mode.
If the piston range displayed in the bottom right cor-
ner of the screen contains a number outside the
range of 200 to 4650, error code E50 will be gener-
ated. A number outside this range means that
either the linear position sensor is not properly
installed or there is a problem with the shot control-
ler electronics. Error code E50 will be generated
until the problem is corrected.