Mount the Converter

Mount the converter (Fig.1) to the wall or other secure

surface using the mounting holes. Do not let the unit

hang unsecured.

CAUTION

Do not mount the pulse converter near a heat source.

Connect the Converter

NOTE:

When connecting the converter to the pulse

meter, use only the connecting cables permanently

attached to each unit. Do not use extension cables to

lengthen the distance between the pulse meter and the

converter.

A distance greater than 24 inches (61

cm) between the units can degrade the signal.

1. Turn off the Electronic Fluid Commander and

unplug it.

2. Connect the converter to the pulse meter first

using the connector with two female sockets.

3. Connect the converter to the Electronic Fluid

Commander (EFC) using the remaining male

connector.

4. Plug in the Electronic Fluid Commander and turn

on the switch at the rear of the control.

Note:

During power--up, all display segments must

show and all stations and dispense lights must light

steadily for 3 to 4 seconds. When the display shows

four dashes, enter your security code. (Refer to the

Electronic Fluid Commander manual for details).

Fig. 1

Female connector

to Pulse Meter

(Graco part number

215474)

Male connector

to EFC

Mounting holes

Mounting holes

TI0708B

Technical Data

Pulse Converter Technical Data

Category

Data

Operating temperature

--4

_

F (--20

_

C) to 176

_

F (80

_

C)

Max. VDC

15 VDC at 20mA

Wiring Gauge Required

18 AWG 2 wire / 90V

Wiring Polarity

Red = + (positive)

g

y

Black = -- (negative)

Summary of Contents for 244342

Page 1: ...c Fluid Commander Meter Pulse Converter Part No 244342 A converter that allows the Graco Pulse Meter 215474 to work with the Electronic Fluid Commander EFC Dispensing Controls 235531 235532 232076 232077 240448 or 241905 for dispensing antifreeze or oil TI0708B GRACO INC P O BOX 1441 MINNEAPOLIS MN 55440 1441 ECOPYRIGHT 2000 GRACO INC Graco Inc is registered to I S EN ISO 9001 ...

Page 2: ... Do not expose Graco hoses to temperatures above 66_C 150_F or below 40_C 40_F D Do not stop or deflect fluid leaks with your hand body glove or rag D Follow appropriate Shutdown Procedures whenever you stop dispensing or clean check or service the equipment D Comply with all applicable local state and national fire electrical and safety regulations FIRE AND EXPLOSION HAZARD Improper grounding poo...

Page 3: ...se meter first using the connector with two female sockets 3 Connect the converter to the Electronic Fluid Commander EFC using the remaining male connector 4 Plug in the Electronic Fluid Commander and turn on the switch at the rear of the control Note During power up all display segments must show and all stations and dispense lights must light steadily for 3 to 4 seconds When the display shows fo...

Page 4: ...anty shall be as set forth above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be brought within two 2 years of the date of sale Graco makes no warranty and disclaims all implied war...

Reviews: