Optional Pump Control Module Kit Operation
310766E
13
F4 Pump Control Module Screen
Screen F4 (see F
. 15) appears when the power is
turned on from the PrecisionFlo Control box. This
screen displays the status of the system at the time the
power was last turned off.
This screen displays the following possible messages:
•
Pump A is empty
•
Pump A is active
•
Pump B is empty
•
Pump B is active
•
B air is not on
•
Filter Plugged
•
Pump Runaway
•
Both Pumps Empty
•
A air is not on
•
Depressurized
Fault Beacon
A flashing or solid beacon light indicates a fault that
must be corrected.
Major Faults
Minor Faults
Start Up Procedure
1.
Turn the power on to the system.
2.
The Pump Control Module Screen displays with the
same information that appeared when the system
was powered off.
3.
Press F3 to navigate to the Depressurization
Screen and then press F2 to pressurize the pump.
Shut Down Procedure
When shutting down the system for an extended period
of time both pumps must be depressurized.
1.
Press F3 on the main screen to navigate to the
Depressurization screen.
2.
Press F1 to depressurize the pumps.
F
IG
. 15
Pump Control Module Screen
Solid Red Light
Both pumps empty
Depressurization
Pump runaway
Flashing Red Light
No air A
No air B
Empty A
Empty B
Plugged filter