![background image](http://html1.mh-extra.com/html/graco/224908/224908_installation-instructions-and-parts-list_2253362026.webp)
26
308302
Technical Data
Category
Data
Maximum fluid output pressure
6.0 MPa, 60 bar (850 psi)
Air input pressure range
243–700 kPa, 2.4–7.0 bar (35–100 psi)
Maximum fluid viscosity
600,000 cps
volume per stroke (dispenses on down-
stroke only)
5.0 cc (0.17 oz.)
Recommended pump speed for continu-
ous operation
40 cpm
Maximum recommended pump speed
60 cpm
Maximum flow (250,000 cps fluid)
940 cc/min (32 oz/min);
0.162 m
3
/min (5.8 scfm) air consumption at 0.7 MPa, 7 bar (100 psi)
Stroke length
19 mm (3/4 in.)
Maximum pump operating temperature
60
_
C (140
_
F)
Air inlet size
1/4 npt(f)
Fluid outlet size
1/4 npt(f)
Weight
approx. 8.4 kg (18.5 lb)
Wetted parts
304 and 17–4 pH Stainless steel; PTFE, fluoroelastomer, PEEK
* Sound pressure level at 0.7 MPa,
7 bar (100 psi), 40 cpm
64.12 dB(A)
* Sound power level at 0.7 MPa, 7 bar
(100 psi), 40 cpm
70.84 dB(A)
* Sound pressure measured 1 meter from the pump resting on the floor. Sound power level measured per ISO standard 9614–2