background image

308-230

7

Installation

04966

04967

Fig. 3

F

KEY

A Husky 307 Pump

B Bleed-Type Master Air Valve

(required for pump)

C Air Supply Line

D Air Line Quick Disconnect

E Master Air Valve (for accessories)

F Air Line Filter

G Gun Air Regulator

H Pump Air Regulator

J Fluid Drain Valve (required)

K Fluid Recirculation Line

L Fluid Suction Line

M Surge Tank and Filter

N Gun Fluid Supply Hose

P Gun Air Supply Hose

R Air Spray Gun

S Pail Cover

Y Ground Wire (included)

See page 9 for grounding instructions.

H

J

A

B

C

D

E

G

K

L

M

N

P

R

S

Y

KEY

A Husky 307 Pump

B Bleed-Type Master Air Valve

(required for pump)

C Air Supply Line

D Air Line Quick Disconnect

E Master Air Valve (for accessories)

F Air Line Filter

G Gun Air Regulator

H Pump Air Regulator

J Fluid Drain Valve (required)

K Fluid Recirculation Line

L Fluid Suction Line

M Fluid Regulator and Gauge

N Gun Fluid Supply Hose

P Gun Air Supply Hose

R Optimiser HVLP Spray Gun

S Pail Cover

Y Ground Wire (included)

See page 9 for grounding instructions.

Air Spray Typical Installation –

Pail Mount Models with Surge Tank

HVLP T

ypical Installation –

Pail Mount Models with Fluid Regulator

F

H

J

A

B

C

D

E

G

K

L

M

N

P

R

S

Y

NOTE:

 Some components shown are

included with the sprayer, depending on the

model. Refer to the parts lists on pages

12–17 for parts included in your sprayer.

NOTE:

 Some components shown are

included with the sprayer, depending on the

model. Refer to the parts lists on pages

12–17 for parts included in your sprayer.

Summary of Contents for 224-833

Page 1: ...t Pressure Model 236 870 Series A Pail Mount Unit with Fluid Regulator Model 224 833 Series B Pail Mount Unit with Fluid Regulator and Hose Kit Model 236 412 Series A Pail Mount Unit with Surge Tank a...

Page 2: ...Graco distributor Do not alter or modify this equipment Use only genuine Graco parts and accessories Check equipment daily Repair or replace worn or damaged parts immediately Do not exceed the maximum...

Page 3: ...and result in a fire or explosion and serious injury Ground the equipment Refer to Grounding on page 9 If there is any static sparking or you feel an electric shock while using this equipment stop pum...

Page 4: ...depth Tighten the nut securely 3 On Models 236 870 and 224 833 assemble the Fluid Regulator Kit items 17 21 24 and 32 as shown in Fig 1 4 Attach the pail cover 2 to a pail of fluid using the thumbscr...

Page 5: ...ts full depth then tighten the nut secure ly with a wrench Push the 0 5 in 13 mm OD flexible tube 29 into the elbow 30 to its full depth then tighten the nut secure ly with a wrench Push the other end...

Page 6: ...kin injury from moving parts or contamination from hazardous fluids A fluid drain valve J is required in your system to relieve pressure in the hose if it is plugged The fluid recirculation valve supp...

Page 7: ...connect E Master Air Valve for accessories F Air Line Filter G Gun Air Regulator H Pump Air Regulator J Fluid Drain Valve required K Fluid Recirculation Line L Fluid Suction Line M Fluid Regulator and...

Page 8: ...Valve required L Fluid Suction Line M Surge Tank and Filter N Gun Fluid Supply Hose P Gun Air Supply Hose R Air Spray Gun S Wall Bracket Y Ground Wire included See page 9 for grounding instructions Ai...

Page 9: ...to the pump grounding strip Z Connect the clamp end of the ground wire to a true earth ground Fig 5 04963 Y Z 34 2 Air and fluid hoses Use only electrically conduc tive hoses 3 Spray gun The spray gu...

Page 10: ...e sure the pump is properly grounded Read FIRE OR EXPLOSION HAZARD on page 3 2 Check all fittings to be sure they are tight Be sure to use a compatible liquid thread sealant or tape on all male thread...

Page 11: ...supplied with Models 236 870 224 833 and 236 412 drains unused fluid back into the fluid container ensuring an even flow at the gun Recirculation also provides gentle fluid agita tion To recirculate...

Page 12: ...rd part 1 111 885 GASKET Vitonr alternative to EPDM shipped loose 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 20 112 026 ELBOW street 3 8 npt m x...

Page 13: ...Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full depth and tighten nut securely with wrench Inser...

Page 14: ...308 325 1 18 237 534 VALVE ball 3 8 npt m x f sst 1 19 111 928 TEE 3 8 npt f run x 3 8 npt m branch sst 1 21 188 089 NIPPLE 3 8 npt x 3 8 18 6 sf sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 0...

Page 15: ...hten nut securely with wrench Insert tube into elbow 15 to full depth and tighten nut securely with wrench Insert tube into connector 16 to full depth and tighten nut securely with wrench 5 6 7 28 1 2...

Page 16: ...npt x 3 8 npt sst 1 22 169 971 FITTING air line 3 8 npt m 1 23 188 077 NIPPLE 1 4 18 npt x 1 4 18 6 sf cst 1 24 188 091 NIPPLE 1 2 npt x 3 8 18 6 sf cst Models 236 628 and 236 414 only 1 188 380 NIPP...

Page 17: ...0 12 13 14 17 23 24 25 26 26 4 5 6 39 40 A A 3 Part of item 17 17a 17b 1 3 4 2 Torque to 35 55 in lb 4 0 6 2 N m Do not over torque Torque to contact plus 1 2 turn Insert tube into elbow 14 to full de...

Page 18: ...mm Pail is not included Maximum pail outer diameter is 12 125 in 308 mm 13 1 in 332 7 mm Model 236 412 Models 236 870 and 224 833 17 5 in 444 5 mm Wall Mounting Hole Layout 5 in 127 mm 0654 Four 0 43...

Page 19: ...236 869 acetal Maximum Fluid Working Pressure 100 psi 0 7 MPa 7 bar Air Pressure Operating Range 15 100 psi 104 700 kPa 1 7 bar Pump Air Inlet Size 1 4 npt f Pump Fluid Inlet and Outlet Size 3 8 npt f...

Page 20: ...ed to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty mu...

Reviews: