308-230
19
Technical Data
Wetted Parts
Pump
See 308–553
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pail Cover (236–870, 224–833,
236–412)
stainless steel
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Fluid Hoses
nylon
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hose Couplings
stainless steel
. . . . . . . . . . . . . . . . . . . . . . .
Surge Tank (236–412, 236–414, 236–628, 236–868,
236–869)
nylon, EPDM or Viton
, stainless steel
. . . . . .
Fluid Regulator (236–870, 224–833)
See 308–325
. . . . . .
Fittings
acetal, stainless steel
. . . . . . . . . . . . . . . . . . . . . . . .
Tubing
nylon
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Suction Tube (236–414 and 236–869)
acetal
. . . . . . . . . . .
Maximum Fluid Working Pressure
100 psi (0.7 MPa, 7 bar)
.
Air Pressure Operating Range
15–100 psi
. . . . . . . . . . . . . . .
(104–700 kPa, 1–7 bar)
Pump Air Inlet Size
1/4 npt(f)
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump Fluid Inlet and Outlet Size.
3/8 npt(f)
. . . . . . . . . . . . . . .
* Sound Data
Pump sound level at 100 psi (0.7 MPa, 7 bar), full flow
85 dB(A)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pump sound level at 70 psi (480 kPa, 4.8 bar),
1 gpm (3.8 lpm)
78 dB(A)
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating Temperature Range: 40
to 150
F (4.4
to 65.5
C)
* Tested to CAGI-PNEUROP–1969
is a registered trademark of the Du Pont Co.
Manual Change Summary
This manual was revised to include the changes from PCN J.
PTFE
PTFE