background image

3

308106

WARNING

INSTRUCTIONS

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

D

This equipment is for professional use only.

D

Read all instruction manuals, tags, and labels before operating the equipment.

D

Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco

distributor.

D

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

D

Check equipment daily. Repair or replace worn or damaged parts immediately.

D

Do not exceed the maximum working pressure of the lowest rated system component. Refer to the

Technical Data

on pages 20 and 21 for the maximum working pressure of this equipment.

D

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the

Tech-

nical Data

section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

D

Do not use hoses to pull equipment.

D

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose

Graco hoses to temperatures above 82

_

C (180

_

F) or below --40

_

C (--40

_

F).

D

Wear hearing protection when operating this equipment.

D

Do not lift pressurized equipment.

D

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin,

inhaled, or swallowed.

D

Know the specific hazards of the fluid you are using.

D

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local,

state and national guidelines.

D

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and

solvent manufacturer.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

D

Keep clear of all moving parts when starting or operating the pump.

D

Before servicing the equipment, follow the

Pressure Relief Procedure

on page 9 to prevent the

equipment from starting unexpectedly.

Summary of Contents for 223843

Page 1: ...instructions See page 2 for Table of Contents Part No 223843 Series A 30 1 Ratio Presidentr Pump 3600 psi 25 0 MPa 250 bar Maximum Fluid Working Pressure 120 psi 0 8 MPa 8 bar Maximum Air Input Pressu...

Page 2: ...o Standard Warranty 24 Graco Information 24 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions Caution Symbol CAU...

Page 3: ...Do not use hoses to pull equipment D Route hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 82_C 180_F or below 40_C 40_F D Wear...

Page 4: ...ment D Check the hoses tubes and couplings daily Replace worn damaged or loose parts immediately Permanently coupled hoses cannot be repaired replace the entire hose D Use only Graco approved hoses Do...

Page 5: ...5 308106 Notes...

Page 6: ...ombined hose length to ensure grounding continuity 3 Air compressor follow manufacturer s recommen dations 4 Spray gun grounding is obtained through connec tion to a properly grounded fluid hose and p...

Page 7: ...required for pump E Pump Air Regulator F Air Line Filter G Bleed Type Master Air Valve for accessories H Air Supply Hose J Fluid Drain Valve required K Fluid Filter L Fluid Supply Hose M Spray Gun N F...

Page 8: ...t f fluid outlet Use of a short whip hose between the main fluid hose L and the gun M allows freer gun movement Connect a fluid suction hose N to the pump s 3 4 npt m fluid intake Use a grounded 1 2 i...

Page 9: ...Close the bleed type master air valve required in your system 4 Unlock the spray gun trigger safety 5 Hold a metal part of the gun firmly to the side of a grounded metal pail and trigger the gun to re...

Page 10: ...Pressure Relief Procedure on page 9 Relieve the pressure then install the spray tip in the gun With the pump and lines primed and with adequate air pressure and volume supplied the pump will start and...

Page 11: ...n page 9 Shutdown and Care of the Pump For overnight shutdown relieve the pressure Always stop the pump at the bottom of the stroke to prevent the fluid from drying on the exposed displacement rod and...

Page 12: ...trokes Insufficient air pressure closed or clogged air valves etc Open clean Exhausted fluid supply Refill purge all air from pump and fluid lines Clogged fluid line valve etc Clear Packing nut 4 too...

Page 13: ...ECONNECTING THE DISPLACEMENT PUMP 1 Screw the displacement rod 19 into the base of the air motor 101 Install the cotter pin 105 Orient the pump s fluid outlet to the air motor s air inlet as was noted...

Page 14: ...nger over the surface or hold the part up to the light at an angle Be sure the ball seats of the piston 2 and intake valve housing 1 are not chipped or nicked Replace any worn or damaged parts NOTE If...

Page 15: ...1 3 4 2 Torque to 18 20 ft lb 24 27 N m 1 Torque to 25 30 ft lb 34 41 N m 2 Torque President to 25 30 ft lb 34 41 N m Monark to 15 20 ft lb 20 27 N m 3 Torque to 65 75 ft lb 88 102 NSm 4 5 6 Lips of...

Page 16: ...pages 18 and 19 for parts 1 105 101946 PIN cotter stainless steel 0 12 3 2 mm x 1 5 3 8 mm 1 106 101566 NUT lock 3 8 16 3 107 156082 SEAL o ring nitrile rubber 1 110 168221 ROD tie carbon steel 4 5 11...

Page 17: ...es 18 and 19 for parts 1 105 101946 PIN cotter stainless steel 0 12 3 2 mm x 1 5 3 8 mm 1 106 101566 NUT lock 3 8 16 3 107 156082 SEAL o ring nitrile rubber 1 110 164722 ROD tie carbon steel 4 375 112...

Page 18: ...18 308106 Parts Model 223842 Series B Severe Duty Stainless Steel Displacement Pump Includes items 1 22 13 4 18 8 17 3 9 10 12 17 13 8 18 14 6 2 19 16 22 15 7 1...

Page 19: ...GASKET flat PTFE 1 10 24C500 SLEEVE housing stainless steel 1 12 186184 RETAINER packing stainless steel 1 13 164862 V PACKING PTFE 6 REF PART NO NO DESCRIPTION QTY 14 186179 PIN ball stop stainless...

Page 20: ...red flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressure To find Pump Air Consumption...

Page 21: ...Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressure To find Pump Air...

Page 22: ...B C Model 223843 30 in 14 8 in 15 2 in 762 mm 376 mm 386 mm 223844 28 4 in 13 3 in 15 1 in 722 mm 338 mm 384 mm 1 2 npt f AIR INLET 3 8 npt f FLUID OUTLET 0 28 7 1 mm DIA 5 0 127 mm 2 5 64 mm 4 38 11...

Page 23: ...23 308106 Notes...

Page 24: ...incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be...