background image

4

308106

WARNING

SKIN INJECTION HAZARD

Spray from the gun/valve, hose leaks, or ruptured components can inject fluid into your body and

cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the

skin can also cause serious injury.

D

Fluid injected into the skin might look like just a cut, but it is a serious injury.

Get immediate medi-

cal attention.

D

Do not point the gun at anyone or at any part of the body.

D

Do not put your hand or fingers over the spray tip.

D

Do not stop or deflect leaks with your hand, body, glove or rag.

D

Do not “blow back” fluid; this is not an air spray system.

D

Always have the tip guard and the trigger guard on the gun when spraying.

D

Be sure the gun trigger safety operates before spraying.

D

Lock the gun trigger safety when you stop spraying.

D

Follow the

Pressure Relief Procedure

on page 9 whenever you: are instructed to relieve pres-

sure; stop spraying; clean, check, or service the equipment; and install or clean the spray tip.

D

Tighten all fluid connections before operating the equipment.

D

Check the hoses, tubes, and couplings daily. Replace worn, damaged, or loose parts immediately.

Permanently coupled hoses cannot be repaired; replace the entire hose.

D

Use only Graco approved hoses. Do not remove any spring guard that is used to help protect the

hose from rupture caused by kinks or bends near the couplings.

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and

result in a fire or explosion and serious injury.

D

Ground the equipment and the object being sprayed. Refer to

Grounding

on page 6.

D

If there is any static sparking or you feel an electric shock while using this equipment,

stop spray-

ing immediately.

Do not use the equipment until you identify and correct the problem.

D

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid

being sprayed.

D

Keep the spray area free of debris, including solvent, rags, and gasoline.

D

Electrically disconnect all equipment in the spray area.

D

Extinguish all open flames or pilot lights in the spray area.

D

Do not smoke in the spray area.

D

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

D

Do not operate a gasoline engine in the spray area.

Summary of Contents for 223843

Page 1: ...instructions See page 2 for Table of Contents Part No 223843 Series A 30 1 Ratio Presidentr Pump 3600 psi 25 0 MPa 250 bar Maximum Fluid Working Pressure 120 psi 0 8 MPa 8 bar Maximum Air Input Pressu...

Page 2: ...o Standard Warranty 24 Graco Information 24 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions Caution Symbol CAU...

Page 3: ...Do not use hoses to pull equipment D Route hoses away from traffic areas sharp edges moving parts and hot surfaces Do not expose Graco hoses to temperatures above 82_C 180_F or below 40_C 40_F D Wear...

Page 4: ...ment D Check the hoses tubes and couplings daily Replace worn damaged or loose parts immediately Permanently coupled hoses cannot be repaired replace the entire hose D Use only Graco approved hoses Do...

Page 5: ...5 308106 Notes...

Page 6: ...ombined hose length to ensure grounding continuity 3 Air compressor follow manufacturer s recommen dations 4 Spray gun grounding is obtained through connec tion to a properly grounded fluid hose and p...

Page 7: ...required for pump E Pump Air Regulator F Air Line Filter G Bleed Type Master Air Valve for accessories H Air Supply Hose J Fluid Drain Valve required K Fluid Filter L Fluid Supply Hose M Spray Gun N F...

Page 8: ...t f fluid outlet Use of a short whip hose between the main fluid hose L and the gun M allows freer gun movement Connect a fluid suction hose N to the pump s 3 4 npt m fluid intake Use a grounded 1 2 i...

Page 9: ...Close the bleed type master air valve required in your system 4 Unlock the spray gun trigger safety 5 Hold a metal part of the gun firmly to the side of a grounded metal pail and trigger the gun to re...

Page 10: ...Pressure Relief Procedure on page 9 Relieve the pressure then install the spray tip in the gun With the pump and lines primed and with adequate air pressure and volume supplied the pump will start and...

Page 11: ...n page 9 Shutdown and Care of the Pump For overnight shutdown relieve the pressure Always stop the pump at the bottom of the stroke to prevent the fluid from drying on the exposed displacement rod and...

Page 12: ...trokes Insufficient air pressure closed or clogged air valves etc Open clean Exhausted fluid supply Refill purge all air from pump and fluid lines Clogged fluid line valve etc Clear Packing nut 4 too...

Page 13: ...ECONNECTING THE DISPLACEMENT PUMP 1 Screw the displacement rod 19 into the base of the air motor 101 Install the cotter pin 105 Orient the pump s fluid outlet to the air motor s air inlet as was noted...

Page 14: ...nger over the surface or hold the part up to the light at an angle Be sure the ball seats of the piston 2 and intake valve housing 1 are not chipped or nicked Replace any worn or damaged parts NOTE If...

Page 15: ...1 3 4 2 Torque to 18 20 ft lb 24 27 N m 1 Torque to 25 30 ft lb 34 41 N m 2 Torque President to 25 30 ft lb 34 41 N m Monark to 15 20 ft lb 20 27 N m 3 Torque to 65 75 ft lb 88 102 NSm 4 5 6 Lips of...

Page 16: ...pages 18 and 19 for parts 1 105 101946 PIN cotter stainless steel 0 12 3 2 mm x 1 5 3 8 mm 1 106 101566 NUT lock 3 8 16 3 107 156082 SEAL o ring nitrile rubber 1 110 168221 ROD tie carbon steel 4 5 11...

Page 17: ...es 18 and 19 for parts 1 105 101946 PIN cotter stainless steel 0 12 3 2 mm x 1 5 3 8 mm 1 106 101566 NUT lock 3 8 16 3 107 156082 SEAL o ring nitrile rubber 1 110 164722 ROD tie carbon steel 4 375 112...

Page 18: ...18 308106 Parts Model 223842 Series B Severe Duty Stainless Steel Displacement Pump Includes items 1 22 13 4 18 8 17 3 9 10 12 17 13 8 18 14 6 2 19 16 22 15 7 1...

Page 19: ...GASKET flat PTFE 1 10 24C500 SLEEVE housing stainless steel 1 12 186184 RETAINER packing stainless steel 1 13 164862 V PACKING PTFE 6 REF PART NO NO DESCRIPTION QTY 14 186179 PIN ball stop stainless...

Page 20: ...red flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressure To find Pump Air Consumption...

Page 21: ...Locate desired flow along bottom of chart 2 Follow vertical line up to intersection with selected fluid outlet pressure curve black Follow left to scale to read fluid outlet pressure To find Pump Air...

Page 22: ...B C Model 223843 30 in 14 8 in 15 2 in 762 mm 376 mm 386 mm 223844 28 4 in 13 3 in 15 1 in 722 mm 338 mm 384 mm 1 2 npt f AIR INLET 3 8 npt f FLUID OUTLET 0 28 7 1 mm DIA 5 0 127 mm 2 5 64 mm 4 38 11...

Page 23: ...23 308106 Notes...

Page 24: ...incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or consequential loss shall be available Any action for breach of warranty must be...

Reviews: