background image

307637S

EN

Instructions - Parts List

Electronic 

POWERFIL

 Metered 

Dispense Pumps

Used for low-volume dispense of petroleum-base lubricants. For professional use only. 

Model 239702

Pump with gallon/quart/liter Electronic Meter

100 psi (0.7 MPa, 7 bar) Maximum Working Pressure

Model 222602

Unmetered pump

100 psi (0.7 MPa, 7 bar) Maximum Working Pressure

Important Safety Instructions

Read all warnings and instructions in this 
manual. Save these instructions. 

 

 

Summary of Contents for 222602

Page 1: ...e lubricants For professional use only Model 239702 Pump with gallon quart liter Electronic Meter 100 psi 0 7 MPa 7 bar Maximum Working Pressure Model 222602 Unmetered pump 100 psi 0 7 MPa 7 bar Maxim...

Page 2: ...d cause serious injury Follow the Pressure Relief Procedure when you stop spraying dispensing and before cleaning checking or servicing equipment Tighten all fluid connections before operating the equ...

Page 3: ...lvents or flu ids containing such solvents Many other fluids may contain chemicals that can react with aluminum Contact your material sup plier for compatibility PERSONAL PROTECTIVE EQUIPMENT Wear app...

Page 4: ...he pump in the bung hole of a fluid supply container Screw the bung adapter A tightly into the hole Raise the pump about 1 2 inch 12 mm from the bottom of the container Tighten the bung adapter screw...

Page 5: ...ee instruction man ual 308687 supplied Troubleshooting Check all possible problems and causes before disas sembling gun Problem Cause Solution Valve will not dispense fluid Pump is not operating Check...

Page 6: ...usting nut 1c upward until a small gap 0 040 in maximum exists between the handle 1b and the valve housing 1k when the valve is reassembled Reinstall the handle on the stem Reinstall the pin NOTE Clea...

Page 7: ...Notes 307637S 7 Notes...

Page 8: ...ousing threads Press fit Turn nut 1c upward until a small gap 0 040 in max exists between the handle 1b and the housing 1k Step 2 under maintenance Ref Part Description Qty 101 222103 PUMP see 307906...

Page 9: ...Parts 307637S 9 Technical Data See manual 308687 for electronic meter technical data See manual 307906 for pump technical data 13 9 14 18 12 101 20b 20c 20a 20d 20g 20e 20f 16 11 22 1p 1 1n 1p 1n...

Page 10: ...f the equipment does not disclose any defect in material or workmanship repairs will be made at a reasonable charge which charges may include the costs of parts labor and transportation THIS WARRANTY...

Reviews: