60 in. (1.5 m) Maximum Tank Height

PUMP MODEL CHART

 
 

No. of

Stages

 Corrosion Resistant

Standard size for 60 in.

(152cm) max. tank

height

        Waterborne

 Standard size for 60 in.

(152 cm) max. tank

height

Model No.

Model No.

6

223806

223706

7

223807

223707

8

223808

223708

9

223809

223709

10

223810

223710

11

223811

223711

12

223812

223712

13

223813

223713

14

223814

223714

15

NONE

237015

STANDPIPE

66 in. (1.7 m) high. Purchase separately.

Diameter

Stainless Steel

Model No.

Carbon Steel

Model No.

          8 in.

(203 mm)

208995

214644

        11 in.

(279 mm)

904628*

903683*

* Adapter plate 903688 is required with this stand.

Order separately.

GRACO INC.

P.O. BOX 1441

MINNEAPOLIS, MN

55440–1441

COPYRIGHT 2019, GRACO INC.

Graco Inc. is registered to I.S. EN ISO 9001

Summary of Contents for 208995

Page 1: ...T No of Stages Corrosion Resistant Standard size for 60 in 152cm max tank height Waterborne Standard size for 60 in 152 cm max tank height Model No Model No 6 223806 223706 7 223807 223707 8 223808 22...

Page 2: ...Accessories 26 Technical Data 29 Warranty 30 Phone Numbers 30 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions...

Page 3: ...IRE EXPLOSION AND ELECTRIC SHOCK HAZARD Improper grounding poor ventilation open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury Ground the equipm...

Page 4: ...Valve M Open to Air N Air Blowdown Valve O To Spray Booth P Fluid Filter Q Line Isolation Valve R Filter Drain Valve S Standby Pump System Blow down Connection Valve T To Standby Pump U Outlet Pressur...

Page 5: ...nt you plan to use Keep in mind that sharp corners and fittings between lengths of pipe or tubing may cause flow restrictions and fluid breakdown Use the longest lengths of pipe or tubing available to...

Page 6: ...ce the motor coupler 29 on the motor shaft A pushing it up well beyond the end of the shaft Lightly snug the setscrew B Lower the motor onto the pump base making sure the motor locating flange seats p...

Page 7: ...flushed and primed with fluid as instructed below Do not flush the pump with any acid caustic or abrasive flush solution line stripper of any type The pump is designed to circulate automotive paint c...

Page 8: ...tank you have been using is completely exhausted 8 Flushing paint from system Consult the paint supplier for a compatible solvent for flushing paint from the system Water reducible paints should use...

Page 9: ...ubricating 03122 Fig 3 1 1 Grease here 54 3122B Thrust Bearing Temperature Monitoring The 3 8 npt plug 54 can be removed from the pump base to install a temperature sensor to monitor thrust bearing te...

Page 10: ...2 Increased flow rate 2 Adjust back pressure valve 3 Parts worn or damaged 3 Repair pump 4 Air entrained in fluid 4 Purge air See Startup Proce dure on page 7 Pump runs but pressure very low or unste...

Page 11: ...cosity fluid such as paint Prob lem should clear up after flush adjustment nut opening flushing material lem should clear up after flush ing is completed Noisy pump 1 Improper coupler clearance 1 Ens...

Page 12: ...11 25 and lift out the coupling assembly 58 6 Remove the bearing support 22 and key 58b from the shaft 33 7 Remove the adjusting nut lockscrew and plug 19 27 Then remove the adjusting nut 35 03123 Fig...

Page 13: ...e pump base and into the hole in the adjusting nut 35 without forcing it Install the plug 27 If necessary turn the adjusting nut a little in the same direction as pump rotation until the plug goes in...

Page 14: ...14 308060 Service Fig 6 03125 58 33 Tool 178779 0 25 in 6 3 mm 28 A 58b 22 35 Notch 41a 33 21 40 B 19 25 11 10 58 6 3126B 62...

Page 15: ...39 mm 31 A 17 14 14 38 33 35 58 29 1 2 3 3 Repairing Shaft Bearings Impellers and Seals Disassembly NOTE Remove the pump from the regular stand 1 Support the pump in a vertical position on the access...

Page 16: ...ed Install new o rings 9 on all impeller bowls 37b and the intake bowl 36a then lubricate the o rings in place Be sure the impeller nuts 32 rotate freely on the collets 7 To replace the bearings a Use...

Page 17: ...take bowl in a vise 10 Assemble the first impeller 30 collet 18 and impeller nut 32 onto the shaft 33 See Fig 14 Push downward on the impeller and hold it with the spanner wrench 616637 while tighteni...

Page 18: ...OTE Be sure the pump base 31 is clean and that a new base bearing 39 has been installed 1 Install the slinger 40 in the pump base with the flange down Use a wooden dowel just under 0 75 in 19 mm diame...

Page 19: ...19 308060 Notes...

Page 20: ...60 Pump 48 29 5 6 58d 58c 28 58a 10 11 25 22 8 35 13 41a 41b 41c 41d 31 57 52 56 1 23 40 20 21 3 34 7 39 12 16 27 26 19 4 2 24 54 14 14 17 38 33 9 32 30 18 14 17 37a 37b 17 15 9 32 30 36b 36a 18 58b...

Page 21: ...1711 PLUG special 1 28 168500 NUT shaft 1 29 COUPLING motor 170067 fits 1 38 35 mm motor shaft 1 169445 fits 1 12 28 4 mm motor shaft 1 30 170748 IMPELLER pump 1 Stage 31 186096 BASE pump 1 32 170770...

Page 22: ...ump 48 29 5 6 58d 58c 28 58a 10 11 25 22 8 35 13 41a 41b 41c 41d 31 57 52 56 1 23 40 20 21 3 34 7 39 12 16 27 26 19 4 2 24 54 14 14 17 38 33 9 32 30 18 14 17 37a 37b 17 15 9 32 30 36b 36a 18 58b 41e 3...

Page 23: ...1 27 171711 PLUG special 1 28 168500 NUT shaft 1 29 COUPLING motor 170067 fits 1 38 35 mm motor shaft 1 169445 fits 1 12 28 4 mm motor shaft 1 30 170748 IMPELLER pump 1 Stage 31 186266 BASE pump 1 32...

Page 24: ...74 mm 24 5 622 mm TI0569 2 npt inlet Pump No of Stages Weight lb kg 223806 223706 6 205 92 223807 223707 7 207 93 223808 223708 8 208 94 223809 223709 9 210 94 223810 223710 10 211 95 223811 223711 11...

Page 25: ...25 308060 Notes...

Page 26: ...sition maintaining alignment Back Pressure Valve 208997 180 psi 1 2 MPa 12 bar Controlled Working Pressure 200 psi 1 4 MPa 14 bar Maximum Working Pressure Stainless Steel 0 5 in 12 7 mm dia orifice 1...

Page 27: ...1B157 15 230 460 Inverter Duty 213049 51B778 10 230 460 Inverter Duty 213049 116228 10 380 Inverter Duty 213049 Adapter Kit 213049 For all 10 HP motors and 15 HP Electric U Frame Motors Includes adapt...

Page 28: ...tors and 15 HP Electric U Frame Motors Includes adapter plate coupling insert screws and washers Adapter Kit 916340 For 15 HP T Frame and 20 HP motors Includes adapter plate coupling coupling insert s...

Page 29: ...0 Technical Data Power Supply required 220 575 Volt AC 3 phase 50 60 Hz Flow Rate 0 50 gpm 0 189 liter min Fluid Inlet and Outlet Size 2 in npt f Wetted Parts Stainless Steel PTFE FKM acetal PTFE Coat...