background image

307277 5

Operation

Provide clean, dry air to the agitator.

CAUTION

Not lubricating the air motor will cause air motor failure.

For automatic lubrication of the agitator’s air motor, install

an air line lubricator. Set the lubricator feed rate at 1 drop

of oil per minute for high speed or continuous duty usage.

Do not overfeed oil or exhaust air may become

contaminated. To manually lubricate the air motor, see

Lubricating the Air Motor

on page 6.

To order a 3/8”

npt air line lubricator, order Part No. 214847.

Use the needle valve (201) to control the speed of the

motor. Do not exceed 0.7 MPa (7 bar, 100 psi) air

pressure. Always use the lowest agitator speed

necessary to thoroughly mix the material. Excessive

speeds cause the fluid to aerate.

WARNING

To reduce the risk of serious, including amputation

of fingers or splashing fluid in the eyes or on the

skin, always fully close the agitator needle valve

(201) and disconnect the agitator air line before

raising the drum cover, and before checking or

repairing the agitator.

Summary of Contents for 205715

Page 1: ...0 1441 Copyright 1977 Graco Inc is registered to I S EN ISO 9001 Model 205715 Agitator For mastic fluids 0 7 MPa 7 bar 100 psi Maximum Working Pressure 307277L EN Important Safety Instructions Read al...

Page 2: ...accessories D Check equipment daily Repair or replace worn or damaged parts immediately D Use fluids and solvents which are compatible with the equipment wetted parts Refer to the Tech nical Data sect...

Page 3: ...the spray area while operating or if fumes are present D Do not operate a gasoline engine in the spray area D Keep a fire extinguisher in the work area TOXIC FLUID HAZARD Hazardous fluid or toxic fum...

Page 4: ...cover plate from the drum cover 2 Loosen the nuts 206 and screws 210 and disassemble the shaft clamp 224 3 Loosen the setscrews 208 while holding the agitator propellers 219 to the shaft Use the 5 16...

Page 5: ...Lubricating the Air Motor on page 6 To order a 3 8 npt air line lubricator order Part No 214847 Use the needle valve 201 to control the speed of the motor Do not exceed 0 7 MPa 7 bar 100 psi air pres...

Page 6: ...cated pumps is Gast Flushing Solvent Gast Part No AH255 or AH255A Loctite Safety Solvent or Inhibisol Safety Solvent 1 Disconnect the air line and muffler 2 Add several teaspoons of solvent directly i...

Page 7: ...SHER spring 1 4 2 208 100053 SCREW soc hd cup pt set 5 16 x 1 4 6 209 100206 BUSHING hex 1 2 x 1 4 npt 1 210 100270 SCREW hex hd cap 1 4 20 x 5 8 2 211 100633 WRENCH 5 6 1 212 100639 LOCKWASHER ext sh...

Page 8: ...h above The buyer agrees that no other remedy including but not limited to incidental or consequential damages for lost profits lost sales injury to person or property or any other incidental or conse...

Reviews: