4 307277
Installation
air line lubricator
agitator motor
air line filter
air regulator
and gauge
mix tank
(reference only)
Typical Installation
Grounding
Proper grounding is an essential part of maintaining a
safe system.
To reduce the risk of static sparking, the mounting
cover and all electrically conductive objects or devices
in the spray area
must
be properly grounded. Check
your local electrical code for detailed grounding
instructions for your area and type of equipment.
To ground the agitator,
connect one end of the
ground wire (A) to the ground connector (B) on the rim
of the drum cover. See Fig. 1. Connect the other end of
the ground wire to a true earth ground.
For a ground wire and clamp, order Part No. 237569.
A
Fig. 1
B
Installing the Agitator
This air operated agitator is for use with heavy materials,
such as mastics. It has a 2.5 HP, 1000 RPM motor, and
a shaft length of 825 mm (33.5 in.).
1. Remove the cover plate from the drum cover.
2. Loosen the nuts (206) and screws (210) and
disassemble the shaft clamp (224).
3. Loosen the setscrews (208) while holding the agitator
propellers (219) to the shaft. Use the 5/16 in. wrench
(211). Remove the propellers.
4. Guide the agitator shaft (223) through the drum cover.
The agitator will sit at an angle.
5. Fasten the agitator support (204) to the drum cover.
6. Assemble the propellers in their original positions and
torque the setscrews to 11 to 15 N
S
m (96 to 132 in-lb).
7. Be sure the agitator shaft (223) is pushed into the
agitator support (204) as far as possible, and the
setscrew (213) is tightened firmly. Use the No. 10
setscrew wrench (215).
8. Position the shaft clamp (224) around the agitator
shaft (223) and the cylinder of the displacement
pump. Fasten with the screws (210), lockwashers
(207) and nuts (206), and tighten firmly.
201
208
204
223
213
208
219
224
210
207
206
Apply anaerobic
sealant to the
threads. Torque
to 11--15 N
S
m
(96--132 in-lbs) .
MUFFLER
Apply anaerobic
pipe sealant to
the threads.
Torque to
11--15 N
S
m
(96--132 in-lbs).
Press fit
Lubricate
Apply anaerobic
pipe sealant to
the threads.
Fig. 2