3

1. Sensor and LED Arrays:

 Sensor detects the 

presence of hydrocarbon or accelerant vapor. 
Sensor is replaceable. White and UV LED arrays 
encircle the Sensor. 

2. Sensor Guard:

 Provides a protective enclosure for 

the Sensor and LED arrays. 

3.  Coiled Extension Cord:

 

Allows Telescoping Sensor 

Probe to be extended.

4.  Telescoping Sensor Probe:

 

Extends for ease of 

investigation. Retracted: 19.5”, Fully extended: 45”.

5. Locking 

Clips:

 

Lock the Telescoping Sensor Probe at 

desired length. Open both clips to extend or shorten. 

6.  Quick Start Guide:

 

Allows user to operate Model 

950-ASH with minimal instruction.

7.  Audio Sound Port:

 

Produces audible tones when 

hydrocarbons or accelerants are detected. 

8.  Analog Meter Display:

 

Indicates possible presence of 

hydrocarbons or accelerants. The degree and speed of 
needle defl ection is determined by the concentration 
and type of hydrocarbon/accelerant detected.

9. Meter Backlight:

 

Illuminates the meter display in 

low visibility conditions. 

10. 

Hydrocarbon/Accelerant Detection Indicators:

 

When hydrocarbons or accelerants are detected, 
the analog meter display fl ashes red. The higher the 
concentration, the faster the fl ash rate becomes. 

11. Power  Indicator:

 

Blue LED fl ashes until the Sen-

sor has achieved operating temperature. When 
operating temperature has been reached, the blue 
LED will glow. 

12. Mute Indicator:

 

LED glows red when Mute is on.

13. Mute Switch:

 

Silences audio. 

14. High/Low Range Switch:

 HIGH Range allows the 

detection of trace levels of hydrocarbons and ac-
celerants. This is the instrument’s most sensitive de-
tection mode. LOW Range is used when an area of 
concern has high concentrations of hydrocarbons. 
In LOW Range, the sensitivity is reduced to assist in 
pinpointing hydrocarbon / accelerant source. 

15. Power On/Off  and Detection Range Control:

 Turns 

Model 950-ASH on or off  and adjusts Analog Meter 
to be responsive to the presence of hydrocarbons 

or accelerants. 

16. 

Low Battery Indicator:

 

Red LED glows when 

battery is low or has been depleted. Model 950-
ASH with low battery 

has less than 60 minutes of 

operating time remaining

 and should be taken out 

of service and recharged immediately.

17. Charging Indicator:

 Glows red when Model 950-ASH 

is charging. Glows green when charging is complete.

18. Light / UV Indicator:

 Glows blue when ultraviolet LED 

array is on. Glows red when white LED array is on.

19. Light / UV Switch:

 Activates the ultraviolet or white 

LED array and meter backlight. 

20. Purge Indicator:

 Flashes red while the Purge func-

tion is active. Glows red when Purge is complete.

21. Purge Switch:

 Turns Purge function on or off . Purg-

ing clears the Sensor of any absorbed contaminants. 

22. USB Charging Jack:

 Remove the protective cap and 

plug into a USB charger. 

23. Rubber Grip

 for ease of handling and operation. 

SPECIFICATIONS

Dimensions:

 3-1/4” wide by 3-1/4” deep by 19-1/2” long. 

Length fully extended: 45”.

Weight:

 2.2 lbs (1kg). 

Enclosure:

 Corrosion resistant, powder coated steel.

Battery:

 rechargeable Lithium-ion. 

Battery Run Time:

 up to 7-8 hours of continuous 

operation.

Battery Charging:

 +5V USB adapter powered from 

120VAC wall plug charger. 

Battery Charging Time:

 approximately 24 hours to fully 

charge from Low Battery Indication. 

Sensor: 

Solid State Metal Oxide Semiconductor. 

White LED:

 8 solid state white LEDs arrayed around Sensor.  

Ultraviolet (UV) LED:

 8 long-wave ultraviolet (395nm) 

LEDs arrayed around Sensor. 

MODEL 950-ASH FEATURES

Summary of Contents for 950-ASH

Page 1: ...MODEL 950 ASH Arson Scanner Hydrocarbons and Accelerants Detector OPERATION AND MAINTENANCE...

Page 2: ...nsor Guard 20 Purge Indicator 5 Locking Clips 12 Mute Indicator 13 Mute Switch 23 Rubber Grip 8 Analog Meter Display 6 Quick Start Guide 11 Power Indicator 3 Coiled Extension Cord MODEL 950 ASH FEATUR...

Page 3: ...an area of concern has high concentrations of hydrocarbons In LOW Range the sensitivity is reduced to assist in pinpointing hydrocarbon accelerant source 15 Power On Off and Detection Range Control T...

Page 4: ...rument is ready for use During the warmup cycle you may observe a deflection of the needle and rapid flashing of red LEDs on the Analog Meter Display This action is normal and will cease as the detect...

Page 5: ...ite LED arrays function independently of each other and cannot be used simultaneously It is desirable to use the ultraviolet LED array in as little ambient light at the investigation scene as possible...

Page 6: ...time Check the top layer of debris first before digging to obtain suspect material Positive samples may be ob tained from a suspect area many hours or even days after a fire has occurred STORAGE and M...

Page 7: ...zed away and only the odorizer remains The hydrocarbon or accelerant might not be vaporizing due to many factors including temperature and type of hydrocarbon or acceler ant Allow sufficient time for...

Page 8: ...ion 305 Bend Hill Road Fredonia PA 16124 U S A Grace Industries Inc shall not be liable for any direct incidental or other consequential loss or damage arising out of failure of the device to operate...

Reviews: