29
EN
Code
Message
Limit
Action
F-05C7
High Battery Voltage -
Warning
116V
The operator should leave scooter in idle stage
(ignition ON) for 2-3 minutes, battery balancing
in process
F-05C8
High Capacitor Voltage
Warning
150V
The operator should leave scooter in idle stage
(ignition ON) for 2-3 minutes, battery balancing
in process
F-05C9
Motor in low voltage
cutback
84V - GO! S1.2/GO! S1.2+;
60V - GO! S2.4/GO! S2.4+
F-0601
Low Scooter Temperature
- Warning
-30 ⁰C
The operator should allow the scooter to warm
to room temperature before resuming to ride
the scooter.
F-0602
High Scooter Temperature
- Warning
80 ⁰C
The operator should allow the scooter to cool to
room temperature before resuming to ride the
scooter.
F-0603
High Motor Temperature
- Warning
130 ⁰C
The operator should allow the motor to cool to
room temperature before resuming to ride the
scooter.
F-0604
Low Motor Temperature -
Warning
-30 ⁰C
The operator should allow the motor to warm to
room temperature before resuming to ride the
scooter.
High
Curr
High current due to
battery regenaration
n/a
No action necessary, not a fault indication.
Summary of Contents for GO! S1.2
Page 2: ......
Page 3: ...GOVECS GO S1 2 GO S2 4 www govecs com USER S MANUAL AND SERVICE BOOK...
Page 39: ...www govecs com BEDIENUNGSANLEITUNG UND SERVICEHEFT GOVECS GO S1 2 GO S2 4...
Page 75: ...www govecs com MANUAL DE USUARIO I LIBRO DE MANTENIMIENTO GOVECS GO S1 2 GO S2 4...
Page 111: ...www govecs com MANUEL D UTILISATION ET CARTE DE SERVICE GOVECS GO S1 2 GO S2 4...
Page 147: ...www govecs com LIBRETTO DI ISTRUZIONE E MANUTENZIONE GOVECS GO S1 2 GO S2 4...
Page 183: ...www govecs com GEBRUIKERSHANDLEIDING SERVICE BOEK GOVECS GO S1 2 GO S2 4...
Page 219: ...219 NL...