2
SAFETY INSTRUCTIONS
TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR
MAJOR PROPERTY DAMAGE, READ AND FOLLOW ALL
SAFETY INSTRUCTIONS IN MANUAL AND ON PUMP.
This is a
SAFETY ALERT SYMBOL
. When
you see this symbol on the pump or in the
manual, look for one of the following signal
words and be alert to the potential for per-
sonal injury or property damage.
Warns of hazards that
WILL
cause serious
personal injury, death or major property
damage.
Warns of hazards that
CAN
cause serious
personal injury, death or major property
damage.
Warns of hazards that
CAN
cause personal
injury or property damage.
NOTICE:
INDICATES SPECIAL INSTRUCTIONS
WHICH ARE VERY IMPORTANT AND
MUST BE FOLLOWED.
THIS MANUAL IS INTENDED TO ASSIST IN THE
INSTALLATION AND OPERATION OF THIS UNIT
AND MUST BE KEPT WITH THE PUMP.
MAINTAIN ALL SAFETY DECALS.
UNIT NOT DESIGNED FOR USE
WITH HAZARDOUS LIQUIDS OR
FLAMMABLE GASES.
NOTICE:
INSPECT UNIT FOR DAMAGE AND
REPORT ALL DAMAGE TO THE CARRIER
OR DEALER IMMEDIATELY. DO NOT USE
PUMP IF DAMAGE IS SUSPECTED.
Description and Specifi cations
• The Prime Line SP Series embraces a line of end suction
single stage, self-priming centrifugal pumps for lawn
sprinkling, HVAC systems, and general water transfer.
• Casing is cast iron construction with tapped openings
provided for vacuum gauge and casing drain.
• Impeller is bronze, enclosed design, balanced for smooth
operation and keyed to motor shaft.
• ALL motors are NEMA standard, 3500 RPM, open drip
proof or TEFC enclosure.
DANGER
WARNING
WARNING
Hazardous fluids
can cause fire,
burns or death.
Engineering Data
Prime Line SP Data
Model
Impeller
HP
Suction
Discharge Phase/Hz
Size
Flange
30SPH1
5.94
3 SPF20
1½
1/60
30SPH3
3/60
30SPM1
5.06 3 SPF25 2
1/60
30SMP3
3/60
50SPH1
6.19 5 SPF25 2
1/60
50SPH3
3/60
50SPM1
5.82 5 SPF30
2½
1/60
50SPM3
3/60
Table 1
• Maximum Liquid Temperature: 160º F (71º C)
• Starts per hour: 20 – evenly distributed.
Piping
• Pump
MUST
be installed horizontally on a solid fl at surface,
with discharge on top.
• Allow adequate space for servicing and ventilation. Protect
the unit from weather and water damage due to rain or
fl ooding or freezing temperatures.
• Piping should be no smaller than the suction and discharge
connections and kept as short as possible, avoiding unneces-
sary fi ttings to minimize friction losses. See Table 1.
• All piping
MUST
be independently supported and
MUST
NOT
place any piping loads on the pump.
NOTICE:
DO NOT FORCE PIPING INTO PLACE AT
PUMP SUCTION AND DISCHARGE
CONNECTIONS.
• The use of Tefl on™ tape, or equivalent, is recommended for
ALL
pipe joints.
• All pipe joints
MUST
be airtight.
PIPING – SUCTION
• Total suction lift, including elevation and pipe friction loss,
should not exceed 25 feet.
• Install an airtight union in the suction line close to the pump.
See Figure 1.
Figure 1
PRIMING
OPENING
FUSED OR
CIRCUIT BREAKER
DISCONNECT MEANS
DISCHARGE
SUCTION
UNION
CAUTION