Installation, start-up and servicing 

General installation  

Only allow qualified personnel to work on the installation. Connect joints or flanges correctly to the inlet 

and outlet joint. Handle the filter with great care. The tube is very fragile. Remember that any 

ferromagnetic tools and components are attracted to the magnet and may damage it. 

Installation Pneumatic bar CIP filters 

DIN11864-1:2008 Aseptic screwed pipe connection, standard type 
DIN11864-2:2008 Aseptic flanged pipe connection, standard type 
DIN11864-3:2008 Aseptic clamp pipe connection, standard type 
For other options consult EHEDG Position Paper “Pipeline and Process connections” 
 

                           

 

 

 

 

General start-up 

Ensure that: 

  The device has no damages or malfunctions and all connections, whether mechanical or 

pneumatic, are made properly. 

  The filter correctly is installed and at the proper work height. Never install with both the two 

connection flanges and the magnet bar in a horizontal position. 

 

Start-up pneumatic bar filters 

Test the pneumatic bar operation with a paperclip. It should react if the magnet is operated. 
 

Servicing 

If the magnet bar tube is damaged or dented, check that it still operates correctly.  
Spare parts include the pneumatic magnet bar and the seals. The seals must be replaced every year. 
Goudsmit Magnetic Systems can offer a yearly inspection with a replacement of seals and magnetic 

inspection report and certificate. 
 

Storage and dismantling 

When recycling the device at the end of its technical life, dispose of correctly and according to local 

regulations.  

Recommended  

set-up for 

CIP applications 

Summary of Contents for SFH Hygienic Series

Page 1: ...magnetic filter Hygienic series SFH GOUDSMIT Magnetic Systems B V P O Box 18 5580 AA Waalre Petunialaan 19 5582 HA Waalre The Netherlands Tel 31 0 40 2213283 Internet www goudsmitmagnets com E mail in...

Page 2: ...on start up and servicing 10 The information we supply may only be used for service or operation of the product It may not be disclosed to any third parties without our prior written permission Our pr...

Page 3: ...3 SFH filter manual version 07 2016...

Page 4: ...magnetic field of the device Danger to electronic and mechanical devices Magnetic information carriers or electronic and mechanical devices etc may be destroyed if they enter the magnetic field Warnin...

Page 5: ...5 Identification plate If you need to correspond about your device make a note of the numbers on the identification plate In some cases the plate may be replaced by etched identification numbers...

Page 6: ...move magnet in the out position Ensure enough time is given for the disposal of ferromagnetic particles the drain pipe may also be used for sampling Pneumatically move magnet in the in position Stop f...

Page 7: ...ing valve Normal product flow is resumed When cleaning the filter of ferromagnetic particles without any valves Dispose of ferromagnetic particles through another outlet in the installation Please not...

Page 8: ...e and around the central magnet and the magnet captures ferromagnetic particles When disposing of the particles the central magnet inside the pneumatic bar moves down allowing the particles to be flus...

Page 9: ...cleaning the manual filters of ferromagnetic particles Stop product flow Loosen clamps and remove extractor with magnets unit from the housing Loosen the notched handles and remove the magnet unit fro...

Page 10: ...e has no damages or malfunctions and all connections whether mechanical or pneumatic are made properly The filter correctly is installed and at the proper work height Never install with both the two c...

Reviews: