Device Description HG G-71450/1/3/5-A | English, Revision 02 | Date: 06.06.2019
20
Chapter 3 – Hardware
3.2.3.3 Switch-on Behaviour
After applying the operating voltage, the positioning output is active for the duration
of the reset (approx. 500 ms). To check their function all LEDs except the BUS-LED
are switched on for 500 ms. After approx. 2 s the device is ready for operation.
3.2.3.4 Profibus-Interface
For this antenna the data as well as a status byte are transmitted via the Profibus.
Further information on the Profibus interface and on setting the Profibus address via
the Hex-turn-switch can be found in chapter 6 on page 32.
3.2.3.5 RS 232-Interface
The RS232 interface is used for logging and for the internal monitor program for
configuration, see chapter 9 on page 49.
3.2.4 Transponder Antenna HG G-71453-A (CANopen®)
The antenna is connected via a 5 pin cable. The connectors are M12 circular con
-
nectors. Connection cables with M12 connectors or a CAN terminating resistor
(CAN Terminator) are available as accessories (see Table 3 on page 10).
Figure 9
HG G-71453: Housing Dimensions Transponder Antenna
3.2.4.1 Pin Assignments
Table 10
HG G-71453: Pin assignments of the 5 pin circular connector ST1 (pin)
ST1, male, A-coded
Pin
Assignment
1
+U
B
2
POSI out (20 mA)
3
TxD (RS 232) *)
4
RxD (RS 232) *)
5
GND (data and supply)
*)
The specifications TxD and RxD refer to the antenna.
M12 x 1 circular connector
5 pin (female), A-coded
Position of the ferrite rod
156.5 mm
CANopen® Node ID
5 pin (male), A-coded
M12 x 1 circular connector
5 pin (male), A-coded
M12 x 1 circular connector
1
2
3
4
5