![Gotting HG G-193 0-B Series Manual Download Page 23](http://html1.mh-extra.com/html/gotting/hg-g-193-0-b-series/hg-g-193-0-b-series_manual_2247524023.webp)
Device Description HG G-193x0-B | English, Revision 02 | Date: 07.05.2018
23
Configuration – Chapter 6
6.4.5 (4) CSV
Serial output of the sum and difference signals as Comma Separated Values (CSV). These
values can be written to a file via the terminal program. Those files can then be imported
into a spreadsheet application like Microsoft® Excel® and then evaluated. As long as the
sum voltage is below the threshold 0 is output. The values for the induced voltages are out-
put in mV as shown in Figure 2 on page 9.
Figure 15
Example for a CSV output
Tip
In case you want to have values output at all times you can temporarily set the Detect
threshold in the menu Calibration Config to 0.
ATTENTION!
This is only useful for testing purposes. A threshold of 0 means that the sensor permanently
detects a track. Then this information can no longer be used as an aid to detect whether the
vehicle leaves the track!
Freq. 1
Freq. 2
Freq. 3
Freq. 4
Freq. 5
Energy Track Encoder
Sum1 Diff1 Sum2 Diff2 Sum3 Diff3 Sum4 Diff4 Sum5 Diff5 Sum6
Diff6
Incr. Enc.
Table 9
Meaning of the values output in the menu Serial Data-Stream