Configuration – Chapter 6
•
Firmware Update, s. section 6.4.5 on page 23
6.4.2 (1) Frequency Config
Definition of the six frequencies for which the sum and difference signals are calculated. All
sub menus may be quit by pressing any key that is not used in the respective menu.
Figure 12
Menu Frequency Config
6.4.3 (2) Calibration Config
–
Gain1 / Gain2: Configuration of the gain for the induced voltages. 0 means minimum
gain, 255 is maximum gain. The induced voltages depend on the current in the guide
wire and the distance to the guide wire.
ATTENTION!
In order to avoid overmodulation the gain should not be too high! This means that the sum
of all simultaneously occurring sum and difference voltages has to be less than 3,3V.
–
Threshold: This value (in mV) regulates the sum voltage threshold. If the sum voltage
exceeds this threshold the track detect signal is generated.
Figure 13
Menu Calibration Config
HG 19370 xB V1.01 Frequency Config Goetting KG
Frequencies: 5000 6000 7000 8000 10000 25000
Sum: 0 0 0 0 358 0
Dif: 0 0 0 0 0 0
1: Edit 1. Frequency
2: Edit 2. Frequency
3: Edit 3. Frequency
4: Edit 4. Frequency
5: Edit 5. Frequency
6: Edit Energy Frequency
HG 19370 xB V1.01 Calibration Config Goetting KG
Frequencies: 5000 6000 7000 8000 10000 25000
Sum: 0 0 0 0 358 0
Dif: 0 0 0 0 0 0
Gain 1: 17
Gain 2: 17
Threshold: 10
Lower unsecure Threshold: 5
Upper unsecure Threshold: 150
1: Edit Gain 1
2: Edit Gain 2
3: Edit Threshold
4: Edit lower unsecure Threshold
5: Edit upper unsecure Threshold
+: increase Gain
-: decrease Gain
s: save Gain