16
Tube Removal
Warning
Wear protective gloves when handling broken tube to
avoid risk of injury.
For cleaning and repairing purposes or to do a deep clean of the
GoSun Fusion, the tube can be removed from the rest of the device
with the following procedures: if cleaning, ensure tube is at room
temperature
1. Remove the cooking tray
2. Open both reflectors (see “Open Stove”). (Figure A)
3. Focus on the open end of the product, specifically on the silicone
cushion on the inner face of the end cap.
4. Locate and remove the two bolts that connect the reflector arms
to the end cap. (Figure B)
5. Now on the outer face of the end cap, locate and remove the
three bolts along the bottom. (Figure C)
6. With all five bolts removed, slide the End Cap (with connected
leg) away from the body of the unit. (Figure D).
7. Slide the silicone cushion off of the tube. (Figure D)
8. Carefully remove the tube
9. Reverse steps to install new tube