Operating Instructions
Page 1: ...SECUTEST SI 3 349 613 15 1 12 10 Operating Instructions ...
Page 2: ... 11 12 13 14 6 SECUTEST SI MENU without Function Standard Equipment 1 Input and memory module SECUTEST SI 1 USB connector cable 1 Operating instructions The Driver Control software for installing the USB device driver is available from our website ...
Page 3: ... key 9 Enter key to conclude the entry and go to the next entry prompt 10 Space key to enter spaces 11 Storage key to store the last test report 12 Shift key to shift the keyboard from small letters to capital letters and vice versa Key shifts to full stop Key shifts to underline _ 13 Key to activate the SI module 14 Flap to fix the probe lead in the lid of the SECUTEST Combined keyboard instructi...
Page 4: ...1 Setting the Clock 10 4 2 Enter and Delete Top and Bottom Lines 11 4 3 Clear Memory 11 5 How to Display and Store Reports 12 5 1 How to Display Reports Enter and Store Texts 12 5 2 Automatic Report Storage 14 5 3 Quick Report Storage 15 5 4 Requesting Stored Reports 16 6 Statistics 17 6 1 Getting Started for Statistics Recording 17 6 2 View Statistic Data 18 6 3 Delete Statistic Data 19 7 Operati...
Page 5: ...Page 9 Error Message 21 10 Technical Data 22 11 Maintenance 25 11 1 How to Reset the SI Module 25 11 2 Housing 25 11 3 Device Return and Environmentally Compatible Disposal 25 12 Repair and Replacement Parts Service 26 13 Product Support 26 ...
Page 6: ...erface the stored measured values can be transferred from the SECUTEST SI to the PC archived and pro cessed there with our software packages e g for the preparation of invoices or printed directly into a pre made form Note Transmission of the data from the memory of the SI module to the PC via the RS232 interface is only possible when the SI module is connected to the test instrument Note Data tra...
Page 7: ...tration http www gossenmetrawatt com Products Software Software for Testers 1 2 Application PROFITEST 204 and METRISO 5000 D PI Operation with these test instruments is limited to the function Entry of comments via the alphanumeric keyboard Only the following chap ters are relevant in this context chap 2 Safety Features and Safety Precautions chap 3 1 Installing the SI Module chap 10 Technical Dat...
Page 8: ...g of the SI module has electrically conductive characteristics that are similar to those of metal It must not come into connection with live parts Read the operating instructions carefully and completely before you use your unit and follow them in all respects Data Backup only instruments of the SECUTEST series The measurement report and entry data can be safely stored in the RAM of the SECUTEST S...
Page 9: ...he probe lead will not fall out when the lid is closed 3 2 Activating the SI Module To activate the SI module a connection to the RS232 interface of the SECUTEST must be established and the test instrument must be connected to the mains Attention As long as the signal lamp lights up at the SI module a syn chronization between the test instrument and the SI module is being performed during which no...
Page 10: ...play presented prior to activating the SI module The display shows that 10 of the storage capacity are already occupied When 99 of the memory are filled the data should be transmitted to a PC and stored there Subsequently the existing data must be deleted before new data can be stored to memory Otherwise the messages Memory full and Clear memory in setup appear 4 Presettings Upon selection of the ...
Page 11: ...eyboard Data entry is also possible via barcode reader see chapter 7 page 20 Ð You will get to the next line by pressing the key Ð You can delete the top and bottom lines with the and keys 4 3 Clear Memory To clear the memory press the key on the SI module To stop press the key on the SECUTEST Note With the Clear memory function text information that has been entered consisting of headline and bot...
Page 12: ...ord to be overwritten again and again The test report automatically contains the test result including the measured and limit values as well as information on the visual inspec tion Further specific information on device under test customer and repair can be integrated in the test report by entries via the keyboard or a barcode reader see chapter 7 page 20 The report is presented on the LCD in sev...
Page 13: ...re press the key returns you to the SI menu When storing the report the consecutive ident number is output between date and time Results of the function test Figure at left Info on DUT max 24 charact each Figure at right Info on customer max 24 charact each Information on e g repair max 10 lines of max 24 characters each ENTER STORE ...
Page 14: ...g stored When the SI module is deactivated proceed as follows to activate the Autostore function in the test instrument Ð SECUTEST test instrument Select the desired test at the function selector switch of the test in strument Ð older versions SECUTEST 0701 0702S Set the function selector switch of the test instrument to the MENUE position Ð Move the cursor to Setup and confirm with Ð Move the cur...
Page 15: ...he ident number Here you can enter a maximum of 24 digits and confirm with Ð To store press the key once more The report is stored in the data base of the SI module together with all available data Empty data fields are ignored At the same time you return to measur ing mode to immediately start the next measurement Note If a reset has been made accidentally after the test e g by changing the posit...
Page 16: ...re shown as a maximum Ð Choose Protocol and confirm with Ð Press the help key i on the SECUTEST A list of the stored reports appears Ð Select the desired report using the and keys and confirm with A maximum of 10 stored reports is displayed The next 10 reports are selected by browsing through with the cursor In the presentation of the archived report an on the right hand side of the first bottom l...
Page 17: ... must be defined prior to a measurement by selection of Class If a class name is already entered it must be activated Ð Move the cursor to Class and set menu is displayed Ð Move the cursor to the respective class name and an underline appears at the end of the text Ð If you want another class name delete existing characters with or complete lines with and enter a maximum of eight char acters via t...
Page 18: ...sym bol statistic data have been stored for the respective class All following measurements expand the statistics of the class activated at the time by the additional measured results If new statistic data are to be recorded for an existing class the stored statistic data can be deleted see chap 6 3 Delete Statistic Data 6 2 View Statistic Data Select the Statistics menu to request statistic data ...
Page 19: ...move the cursor to Delete and press Ð Select the class the data of which is to be deleted or Ð Select Delete all to delete the stored statistic data of all classes After all classes are deleted class A is set active and the error type of each class is set to First ...
Page 20: ...eader confirms the correct connection with a double acoustic signal 7 2 Configuring the Barcode Reader The barcode reader B3261 and Z720A are configured for the following barcodes CODE 39 CODE 128 EAN13 12 digits The barcode reader are immediately ready for operation when con nected to a SECUTEST or SECUTEST SI test instrument For operation with PROFITEST 204 the barcode reader has to be configure...
Page 21: ... only possible when the SI mod ule is connected to the test instrument which in turn is connected to the mains Ð Connect the PC to the RS232 connection socket of the SI module via an interface cable 9 Error Message Message when the key has been pressed although there is no free memory STORE ...
Page 22: ...g for connection to a PC or a barcode reader or RFID Scanner USB 4 pin USB1 1 type B for connection to a PC only for transmission of measured data Data Memory RAM data 100 kbytes Real time clock with date battery backed by embedded Lithium cell RS232 Interface Type RS232 serial per DIN 19241 Operating voltage 6 5 V 12 V for connection to test instrument Current consumption 40 mA typical Baud rate ...
Page 23: ...hen connected to the test instrument 5 V DC 10 from the RS232 interface of the test instrument when connected to a PC without connection to the test instrument 5 V DC 10 from the USB interface of the PC Current consumption 40 mA typical Baud rate 9600 bauds Parity none Data bits 8 Stop bit 1 Terminal assignment Type B 4 pin 1 VCC 2 D 3 D 4 GND 1 Enable remote control Plus 2 RXD 3 TXD 4 NC 5 GROUND...
Page 24: ...0 60 Ambient Conditions Operating temperature 0 C 40 C Storage temperature 20 C 60 C Humidity max 75 RH no condensation Electromagnetic Compatibility EMC Interference emission EN 61326 1 2006 class B Interference immunity EN 61326 1 2006 Mechanical Design Protection type IP 20 for the housing Dimensions 240 mm x 81 mm x 40 mm excl knurled screws and ribbon cable Weight approx 0 4 kg ...
Page 25: ... with ElektroG German Electrical and Electronic Device Law This device is not subject to the RoHS directive We identify our electrical and electronic devices as of August 2005 in accordance with WEEE 2002 96 EG and ElektroG with the symbol shown to the right per DIN EN 50419 These devices may not be disposed with the trash Please contact our service department regarding the return of old devices a...
Page 26: ...need service please contact GMC I Service GmbH Service Center Thomas Mann Straße 20 90471 Nürnberg Germany Phone 49 911 817718 0 Fax 49 911 817718 253 E Mail service gossenmetrawatt com www gmci service com This address is only valid in Germany Please contact our representatives or subsidiaries for service in other countries 13 Product Support When you need support please contact GMC I Messtechnik...