5.1.2

Recharging the Batteries

Attention!

!

Use only the charger (Z507A) which is offered as an op-
tional accessory for this instrument to charge the 

batter-

ies

 inserted in the instrument.

Make sure that the following conditions have been fulfilled be-
fore connecting the charger to the charging socket:

 

– rechargeable batteries have been inserted with correct

polarity, 

no

 normal batteries

– The test instrument has been disconnected from the 

measuring circuit at all poles 

– The instrument must remain off during charging.

Recharging of the batteries begins as soon as the charger is con-
nected to the mains and to the charging socket (see figure 2.1). 
Charging takes approximately 5 hours and 30 minutes (integrated 
safety timer) if the batteries have been fully depleted.

Safety Precautions

Do not attempt to recharge alkaline batteries: they may leak, 
explode etc. The test instrument may be severely damaged or 
destroyed as a result.

After initially charging new batteries and after rechargeable 
batteries have not been used for a lengthy period of time (sev-
eral months), operating hours after charging may be signifi-
cantly less than usual. If this is the case, repeat the charging 
procedure several times. 
Autonomous, intelligent charging stations execute charging/
discharging cycles of this sort automatically (see instructions 
included with the charging station). This procedure increases 
the capacity of the batteries, thus making longer periods of 
operation possible between charging cycles.

If no improvement is achieved in this way, one or more of the 
rechargeable batteries may no longer fulfill the original specifi-
cations. If this is the case, the defective rechargeable battery 
should be identified, e.g. with the help of the voltage measure-
ment, and replaced.

Battery capacity is gradually reduced as a result of long and 
frequent use. When you notice that this is the case, all of the 
rechargeable batteries should be replaced.

5.2

Cleaning

Use a soft cloth and soapy water for cleaning. Do not place the 
test instrument back into service until its surface is completely dry.

Attention!

!

Do not use cleaning agents which contain benzine or al-
cohol! Prevent liquids from penetrating into the test in-
strument’s interior.

5.3

Recalibration

The measuring tasks performed with your instrument, and the 
stressing it’s subjected to, influence aging of its components and 
may result in deviation from the specified levels of accuracy.

In the case of strict measuring accuracy requirements, as well as 
in the event of use at construction sites with frequent stress due 
to transport and considerable temperature fluctuation, we recom-
mend a relatively short calibration interval of once per year. If your 

instrument is used primarily in the laboratory and indoors without 
considerable climatic or mechanical stressing, a calibration inter-
val of once every 2 to 3 years is sufficient as a rule.

During recalibration at an accredited calibration laboratory 
(DIN EN ISO/IEC 17025), deviations from traceable standards 
demonstrated by your measuring instrument are documented. 
Ascertained deviations are used to correct display values during 
later use of the instrument.

We would be happy to perform DAkkS or factory calibration for 
you at our calibration laboratory. Further information is available at 
our website:
www.gossenmetrawatt.com (

 Company 

 DAkkS Calibration 

Center 

or

 

 FAQs 

 General – Calibration Questions and 

Answers).

Recalibration of your instrument at regular intervals is essential for 
the fulfillment of requirements according to quality management 
systems per DIN EN ISO 9001.

* Examination of the specification, as well as adjustment, are not included 

in calibration. However, in the case of our own products, any required 
adjustment is performed and adherence to the specification is con-
firmed.

6

Repair and Replacement Parts Service,
Calibration Center and Rental 
Instrument Service

If required please contact:

GMC-I Service GmbH

Service Center

 

Thomas-Mann-Str. 20
90471 Nürnberg, Germany
Phone:

+49 911 817718-0

Fax:

+49 911 817718-253

e-mail

[email protected]

www.gmci-service.com

This address is only valid in Germany. Please contact our repre-
sentatives or subsidiaries for service in other countries.

7

Product Support

If required please contact:

GMC-I Messtechnik GmbH

Product Support Hotline

Phone:

+49-911-8602-0

Fax:

+49 911 8602-709

e-mail

 [email protected]

Summary of Contents for METRALINE ISO CHECK

Page 1: ...Operating Instructions METRALINE ISOCHECK Insulation Resistance Tester 3 349 691 03 2 4 13 ...

Page 2: ...ng The device has been stored under unfavorable conditions for a lengthy period of time The device has been handled impermissibly e g has been dropped from a height of 1 meter or more The test instrument does not function as described in these operating instructions if this is the case we recommend resetting the device as described in section 3 5 on page 7 CAUTION Do not touch electrically conduct...

Page 3: ...s are simultaneously recessed and protected In order to charge batteries which have been inserted into the instrument the flexible test probe s connector plug must be removed and the slide must be pushed to the left so that the socket at the right is made accessible and the charger can be plugged into it Figure 2 2 Detail View of the Back Panel with Battery Compartment Lid 2 2 Control Panel 1 Grap...

Page 4: ...nce voltage to appear at the display Do not remove the test probes prematurely during the course of the measurement because this may lead to distorted mea surement results After insulation measurement has been completed any remaining residual voltage is displayed as UIN which may result from cable capacitance Contact to the device under test must be main tained for as long as a capacitive DUT is b...

Page 5: ...y take several tens of seconds Note Whistling or hissing noises may emanate from the test instrument during measurement 3 3 3 Measurements at Varistors surge protection devices For this measuring function the test instrument generates a rising direct voltage within a range of 50 to 1000 V and at the same time measures current flowing through the device under test As soon as current reaches a level...

Page 6: ...hich may result from cable capacitance Contact to the device under test must be main tained for as long as the capacitive DUT is being discharged via the test instrument s internal resistor The falling voltage value can be observed directly at the UIN display Do not disconnect the DUT until voltage UIN is less than 25 V Comments Before measuring surge protection devices disconnect them from the in...

Page 7: ...ast 750 mAh Number of measurements with batteries at 800 mAh approx 1 000 measurements with 500 V test voltage on 500 k Electrical Safety Measuring category with safety cap applied to test probe CAT III 300 V without safety cap applied to test probe CAT II 300 V Pollution degree 2 Protection class II Mechanical Design Display OLED multicolored graphic Protection IP 43 Dimensions Approx 260 x 70 x ...

Page 8: ...d soapy water for cleaning Do not place the test instrument back into service until its surface is completely dry Attention Do not use cleaning agents which contain benzine or al cohol Prevent liquids from penetrating into the test in strument s interior 5 3 Recalibration The measuring tasks performed with your instrument and the stressing it s subjected to influence aging of its components and ma...

Reviews: