1.4

Applications

The test instrument consists of a compact housing with a pat-
ented means of retaining the second test probe.
The high-contrast, four-color OLED display assures excellent legi-
bility. When performing measurements under unfavorable light 
conditions, measuring point illumination can be switched on – 
white LED at the front.

The test instrument is capable of the following measurements:

Insulation resistance with test voltages of 50 to 1000 V

Surge protection devices with test voltages of 50 to 1000 V

Direct and alternating voltages

1.5

Applicable Standards

Measurement

EMC

Safety

EN 61557-1

EN 55022 class B 

EN 61010-1

EN 61557-2

EN 61326-1

EN61010-031

1.6

Environment

The shipping package is made of recyclable cardboard.
Batteries must be disposed of in accordance with applicable 
regulations.

This device may not be disposed of with the trash. Further 
information regarding the WEEE mark can be accessed 
on the Internet at www.gossenmetrawatt.com by entering 
the search term “WEEE”.

2

Device Description

2.1

Housing

Figure 2.1:

Top View

For transport purposes, the movable test probe can be attached 
to the housing and retained by a magnet such that both metal tips 
are simultaneously recessed and protected.

In order to charge batteries which have been inserted into the 
instrument, the flexible test probe’s connector plug must be 
removed and the slide must be pushed to the left, so that the 
socket at the right is made accessible and the charger can be 
plugged into it.

Figure 2.2:

Detail View of the Back Panel with Battery 

Compartment Lid

2.2

Control Panel

1 Graphic OLED display 

2

START

 key: 

– 

Switch on

Press and hold until the dis-
play lights up. 
– 

Start measurement

Press and hold until measure-
ment starts. 
– 

Measurement point illumina-

tion

Press briefly to switch illumi-
nation on and off. 
– 

Switch off

Press twice briefly to switch 
the instrument off.

3

R

ISO

/U

SPD

 

KEY

For switching between insula-
tion resistance and surge pro-
tection measurement

4 The 

FUNC

 key allows for selec-

tion of the desired type of 
surge protection when U

SPD

 

is activated.

5

U

TEST

 

▲ 

key for selecting 

measuring voltage

6

U

TEST

 

▼ 

key for selecting 

measuring voltage

Figure 2.3:

Control Panel and OLED Display

2.3

Initial Start-Up

After inserting the batteries in accordance with section 5.1 on 
page 7, the measuring instrument is ready for operation.

Fixed Test Probe Attached to the Device

LED

OLED Display

Socket for Flexible Test Probe

Socket for Charger

Plu

g-In

 M

ob

ile T

est

 P

rob

e

Plastic

Control Panel

Housing

Screws for Battery Compartment Lid

Battery Compartment Lid

Serial Plate

3

1

2

4

5

6

Summary of Contents for METRALINE ISO CHECK

Page 1: ...Operating Instructions METRALINE ISOCHECK Insulation Resistance Tester 3 349 691 03 2 4 13 ...

Page 2: ...ng The device has been stored under unfavorable conditions for a lengthy period of time The device has been handled impermissibly e g has been dropped from a height of 1 meter or more The test instrument does not function as described in these operating instructions if this is the case we recommend resetting the device as described in section 3 5 on page 7 CAUTION Do not touch electrically conduct...

Page 3: ...s are simultaneously recessed and protected In order to charge batteries which have been inserted into the instrument the flexible test probe s connector plug must be removed and the slide must be pushed to the left so that the socket at the right is made accessible and the charger can be plugged into it Figure 2 2 Detail View of the Back Panel with Battery Compartment Lid 2 2 Control Panel 1 Grap...

Page 4: ...nce voltage to appear at the display Do not remove the test probes prematurely during the course of the measurement because this may lead to distorted mea surement results After insulation measurement has been completed any remaining residual voltage is displayed as UIN which may result from cable capacitance Contact to the device under test must be main tained for as long as a capacitive DUT is b...

Page 5: ...y take several tens of seconds Note Whistling or hissing noises may emanate from the test instrument during measurement 3 3 3 Measurements at Varistors surge protection devices For this measuring function the test instrument generates a rising direct voltage within a range of 50 to 1000 V and at the same time measures current flowing through the device under test As soon as current reaches a level...

Page 6: ...hich may result from cable capacitance Contact to the device under test must be main tained for as long as the capacitive DUT is being discharged via the test instrument s internal resistor The falling voltage value can be observed directly at the UIN display Do not disconnect the DUT until voltage UIN is less than 25 V Comments Before measuring surge protection devices disconnect them from the in...

Page 7: ...ast 750 mAh Number of measurements with batteries at 800 mAh approx 1 000 measurements with 500 V test voltage on 500 k Electrical Safety Measuring category with safety cap applied to test probe CAT III 300 V without safety cap applied to test probe CAT II 300 V Pollution degree 2 Protection class II Mechanical Design Display OLED multicolored graphic Protection IP 43 Dimensions Approx 260 x 70 x ...

Page 8: ...d soapy water for cleaning Do not place the test instrument back into service until its surface is completely dry Attention Do not use cleaning agents which contain benzine or al cohol Prevent liquids from penetrating into the test in strument s interior 5 3 Recalibration The measuring tasks performed with your instrument and the stressing it s subjected to influence aging of its components and ma...

Reviews: