26
7.2.2
Instrument Setup
1. Select
Setup
>
Instrument Setup
to view or change the current instrument
setup.
Note!
The instrument settings can only be modified if monitoring is off. If mon-
itoring is on, you will receive a warning that the survey settings are "view
only".
Figure 12: Instrument setup
Journal /
Snapshot
Journal Enable
Checkbox enable/disable.
Journal Interval
Sec.
Journal interval entered in seconds.
Value entered: ≥ 1 second
Snapshot Enable Checkbox enable/disable
Snapshot
Interval Sec.
Snapshot interval in seconds.
Value entered: ≥ 60 seconds
Button
Submit
Changes
Click to save the settings.
Button
Discard
Changes