3.18 COMMANDS WAIT

3.19ALARMS

LIST OF ALARMS

In the event of there come commands from user when device is in sleep and 

couldn't process commands, at each wakeup device will wait one minute to receive 

those commands and take precedence to process them then response one 

confirmation message; after 1 min, device would receive and process real-time 

commands then reply accordingly.

The device sends alarm immediately it triggers. The message receive when device is 

in alarm as

follows:

G626 V1.05

GPS 6/77

UTC 11-00.5-14 05:33:47

N23.164479

E113.428606

SPD:0km/h 0

Alarm:

Low inter_Batt

Low Power

Description

SMS Received
G626 V1.05

GPS 6/77

UTC 11-05-14 05:33:47

N23.164479

E113.428606S

PD:0km/h 0

Alarm:Low inter_Batt

Over Speed

G626 V1.05
GPS 6/77
UTC 11-05-14 05:33:47
N23.164479
E113.428606
SPD:0km/h 0
Alarm:Over Speed

16

Summary of Contents for G626

Page 1: ... ...

Page 2: ... Disable Over Speed Alarm Parameter 3 12 Enable Disable SMS when movement trigger 3 13 Location Poll 3 14 Set Time Zone 3 15 Clear Alarm 3 16 Query SIM card balance 3 17 Combine Command 3 18 Commands Wait 3 19 Alarms 3 20 Default Parameters 4 1 Normal Location SMS Format G Mode 4 2 Hyperlink SMS Format W Mode 4 3 Error Command Alert 4 4 Password Modification Successful Confirmation 4 5 User No Set...

Page 3: ...d by Gosafe Company Limited It combines GSM and SMS with GPS to locate your belongings Due to its compact size and long life battery G626 can be easily installed and concealed somewhere in your vehicle motorcycle or boat to track and locate them 1 Back Cover SIM card Holder GPS Battery screws ...

Page 4: ...e 700uA Active Mode 300mA Power Antenna Modem Frequency Internal uBlox LEON G100 Quad band 850 900 1800 1900MHz GPRS Approvals LBS Location Accuracy GSM Antenna Receiver Internal uBlox NEO 6M GPS Sbase engine GPS MCU TI MSP430 12KB RAM 256KB Flash MCU Class 10 4 downlink 2 uplink max 5 Mobile Station Class B AT T R TTE CE GCF FCC PTCRB Anatel IC China SRRC etc 100 to 500m Urban 0 5 to 30km Suburb ...

Page 5: ...ltage detector to offer low voltage alert Internal memory for the data buffer Channels Sensitivity Navigation update Acquisition Location Accuracy 50 Parallel Channels 162dBm 1sec Cold Starts 27s Aided Starts 1s Hot Starts 1s 2 5 to 10m Strong Signals 500 m Weak Signals 3D G Force Sensor Onboard Sensor Flash 10 000 Locations Memory Operating Temperature Storing Temperature Humidity 20 C to 60 C 20...

Page 6: ...according to the below picture 2 QUICK INSTALL INSTRUCTIONS Please do activate the SIM card disable its PIN code function and make sure SIM card has enough balance before operating the device Each time before taking SIM card out of or inserting SIM card into the device you would better cut the power supply or it would damage device and or your SIM card 4 ...

Page 7: ...NO Connect battery to device like the shown in the picture below 1234 UNO 8613912345678 1234 UNO 13912345678 UNO 13912345678 UNO 8613912345678 Message Send SMS Reply with country code without country code Command Control Word 5 ...

Page 8: ...mation SMS for password modification from device Message 1234 UPW 5678 UPW 5678 Send SMS Reply New Password Command Control Word Factory Password Connect USB cable to the device and connect it with the computer For further details please refer to the documents for configuration 6 ...

Page 9: ...e the Work Mode user wants to configure Command Control Word Password 2 6 SET WORK MODE There are 3 different work modes configurable for device according to user s need O S and G To set device in G Work Mode you should send the following SMS command to the SIM card No 7 ...

Page 10: ...2 7 CONFIGURATION Connect USB cable to the device and connect it with the computer For further details please refer to the documents for configuration 8 ...

Page 11: ... 0000 9999 UPW 1234 UPW 1234 UPW 3 3 Setting user password UUM 30M G T UUM 30M G T UUM 3 4 30M upload interval M can be 30 900S 15 59M 1 240H Default 30m G W G upload mode it can be O close uploading G upload GPS data by interval set when there is no GPS data uploading based on base station information S Always upload with LBS location T data format it can be T Text Format W Hyper link Format Sett...

Page 12: ...SM 0 or PSM 32 PSM 0 or PSM 32 The bigger Parameter is the lower power consumption is 00 most performance mode GSM and GPS both are available 32 power save mode the high 4 bits are GPS mode bits the low 4 bits are GSM mode bits 0 Always on GPS GPS ECO mode 1 undefined functions as GPS mode 0 2 open GPS on demand in reservation setting of GPS search time after 3D location delay GPS work time until ...

Page 13: ...mand during the working time recount the time Close module when working time is up 2 open GSM module on demand Open conditions Getting LBS data uploading data according to setting and alarm occurred Then upload all data Wait until the working time If device received command during the working time recount the time Close module when working time is up 3 open GSM module on demand Open conditions Get...

Page 14: ...e recount the time Close module when working time is up 6 open GSM module on demand Open conditions Getting LBS data Uploading SMS data Uploading saved data according to setting and alarm occurred Then upload all data Wait until the working time If device received command during the working time recount the time Close module when working time is up 7 open GSM module on demand Open conditions Getti...

Page 15: ...60S G B TPM1 1H G B Setting uploading TCP server mode TPM 30M G T or TPM0 30M G T or TPM1 30M G T TPM 30M G T or TPM1 30M G T Remarks Reply Command Ctrl Word Description Sr 8 open GSM module on demand Open conditions Getting LBS data Uploading SMS data Uploading saved data according to setting and alarm occurred Then upload all data Then close module Default PSM 00 MTP 20 30 40 MTP 20 30 40 MTP 3 ...

Page 16: ...and last for parameter3 40 seconds the device will regard the vehicle as in stop status Default 10 10 255 SOP 100 120 SOP 100 120 SOP 3 11 Speeding alarm parameters 100 Alert 120 Alarm Default SPO 80 100 MOT 0 MOT 0 MOT 3 12 Motion sensor enable and disable 0 Close shield the function related to motion sensor It won t send any message This can t judge if the vehicle is in motion status or static s...

Page 17: ...ld begin with user password which is followed by commands commands order is flexible Format is as follow First command Second Command Pw Command word Command word Parameter Parameter Parameter If there is duplication of the same command in the same combine command just the last piece of command would be processed if there is error in the command the command with error would be discarded and device...

Page 18: ...would receive and process real time commands then reply accordingly The device sends alarm immediately it triggers The message receive when device is in alarm as follows G626 V1 05 GPS 6 77 UTC 11 00 5 14 05 33 47 N23 164479 E113 428606 SPD 0km h 0 Alarm Low inter_Batt Low Power Description SMS Received G626 V1 05 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606S PD 0km h 0 Alarm Low inter_Ba...

Page 19: ...o Fence Moving When the vehicle I stopped and the movement sensor is enable the device sends move alarm on the trigger of movement sensor G626 V1 05 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E113 428606 SPD 0km h 0 Alarm Moving Anti Jamming This alarm appear if the anti jamming feature is enable and the someone use GSM jammer near the device G626 V1 05 GPS 6 77 UTC 11 05 14 05 33 47 N23 164479 E11...

Page 20: ...P upload 1 Package number of per UDP upload 1 percentage of data buffer per TPC upload 50 percentage of data buffer per UDP upload 50 Over speed 80 100 Enable disable over speed alarm Disable Enable disable vibration sensor Disable Enable disable phone roaming status test Enable Enable disable anti jamming Disable Time zone 0 00 Vibration sensor parameter 10 10 255 Anti jamming parameter 30 20 Bau...

Page 21: ...mat Speed 1km h 39 Device speed and Move Direction TMP 25 6C Temperature PWR 12 5V Power Gosafe G626 V1 05 Device Name and Version MCC 460 Mobile Country Code MNC 1 Mobile Network Code LAC 517A Location Area Code CID 1FB1 Cell Identity TMP 25 6C Temperature PWR 12 5V Power Gosafe G626 V1 05 Device Name and Version MCC 460 Mobile Country Code MNC 1 Mobile Network Code LAC 517A Location Area Code CI...

Page 22: ...e G626 V1 05 UPW 5678 Gosafe G626 V1 05 UNO 8613912345678 Gosafe G626 V1 05 Device Name and Version http m maps yandex ru ll 116 3875 3 9 949328 pt 116 3875 39 949328 z 12 Yandex Link TMP 25 6C Temperature PWR 12 5V Power Gosafe G626 V1 05 Device Name and Version MCC 460 Mobile Country Code MNC 1 Mobile Network Code LAC 517A Location Area Code CID 1FB1 Cell Identity TMP 25 6C Temperature PWR 12 5V...

Page 23: ...us there is an interval between them To check the statuses please count the LED light flashes then compare it to the chart below Status LED Flashes Device Power on LED ON 1sec GSM module ON but unregistered 1 flash at the beginning of each flash cycle GSM module ON and registered 2 flashed at the beginning of each flash cycle GSM module OFF No flash at the beginning of each flash cycle GSM module ...

Page 24: ... card Error 2 flashes Power OFF then check whether SIM installation is good and PIN is disabled Cannot register at GSM network 3 flashes To check whether SIM card is overdue and or device in an area there is no GSM signal GPS module Error 4 flashes Power OFF then check GPS module power supply and communication To check whether there is SIM card SMS SMS Sending Error 5 flashes center set ting error...

Page 25: ...6 APPENDIX 6 1 CHARACTERS FOR COMMANDS 0 A K U E O Y 1 b l v F P Z 2 c m w G Q 3 d n x H R 4 e o y I S Sp 5 f p z J T _ 6 g q A K U 7 h r B L V 8 i s C M W 9 j t D N X 23 ...

Page 26: ...www gosafesystem com ...

Reviews: