![GORMAN-RUPP PUMPS Super T4A71S-B Installation, Operation And Maintenance Manual Download Page 35](http://html1.mh-extra.com/html/gorman-rupp-pumps/super-t4a71s-b/super-t4a71s-b_installation-operation-and-maintenance-manual_2246945035.webp)
OM-05350
SUPER T SERIES
MAINTENANCE & REPAIR
PAGE E - 12
shaft until it seats against the shaft shoulder. Re
move the tape covering the threads. Check to en
sure that the shaft threads are free of any tape resi
due and clean as required before proceeding with
seal installation.
When installing a new cartridge seal assembly
,
remove the seal from the container and lubricate
the external stationary seat O‐ring with light oil.
Slide the seal assembly onto the shaft until the ex
ternal stationary seat O‐ring engages the bore in
the seal plate.
Clean and inspect the impeller as described in
Im
peller Installation and Adjustment
. Install the full
set of impeller shims (27) provided with the seal,
and screw the impeller onto the shaft until it is
seated against the seal (see Figure 6).
O‐RING ENGAGED
WITH SEAL PLATE
BORE
SHEAR RING
(UNSHEARED)
Figure 6. Seal Partially Installed
Continue to screw the impeller onto the shaft. This
will press the stationary seat into the seal plate
bore.
NOTE
A firm resistance will be felt as the impeller presses
the stationary seat into the seal plate bore.
STATIONARY SEAT
FULLY SEATED IN
SEAL PLATE BORE
SHEAR RING
(SHEARED)
Figure 7. Seal Fully Installed
As the stationary seat becomes fully seated, the
seal spring compresses, and the shaft sleeve will
break the nylon shear ring. This allows the sleeve
to slide down the shaft until seated against the
shaft shoulder. Continue to screw the impeller onto
the shaft until the impeller, shims, and sleeve are
fully seated against the shaft shoulder (see Figure
7).
Measure the impeller‐to‐seal plate clearance, and
remove impeller adjusting shims to obtain the
proper clearance as described in
Impeller Instal
lation and Adjustment
.
If necessary to reuse an
old seal
in an emer
gency, carefully separate the rotating and station
ary seal faces from the bellows retainer and sta
tionary seat.
A new seal assembly should be installed
any time
the old seal is removed from the
pump. Wear patterns on the finished faces
cannot be realigned during reassembly.
Reusing an old seal could result in prema
ture failure.
Handle the seal parts with extreme care to prevent
damage. Be careful not to contaminate precision
finished faces; even fingerprints on the faces can
shorten seal life. If necessary, clean the faces with a
non‐oil based solvent and a clean, lint‐free tissue.
Wipe
lightly
in a concentric pattern to avoid
scratching the faces.