Before connecting to the power supply network, install a power
supply cord in the water heater, with a min. diameter of 1.5 mm
2
(H05VV-F 3G 1.5 mm
2
). To do this, the protective cap must be
removed from the water heater.
Connecting the heater to the power supply network must take
place in accordance with the standards for electric appliances.
To comply with the national installation regulations, an all poles
disconnect switch must be installed between the water heater and the power supply
network.
CAUTION: Before any intervention into the interior of the water heater,
disconnect it from the power supply network!
OPERATION AND MAINTENANCE
After connecting to the water and power supply, the heater is ready for use. By
turning the thermostat knob, water temperature can be set between 10 °C and 65 °C
+5 °C/-0 °C. We recommend that the knob be set to the position "eco" ensuring the
most economic operation of the water heater. This way, the water temperature is
maintained at 55 °C while the operation also results in less lime sediment as well as
in less heat losses than is the case at higher temperatures. During the operation of
an electric heater can hear noise in the water heater. The light indicator shows the
operation of the heating element. On the casing of the water heater a bimetal
thermometer is mounted, pointing clockwise (to the right) whenever there is hot water
in the water heater. The thermometer shows the temperature at the place of
installation, while the control knob on the thermostat sets the temperature of water in
the bottom part of the heater. As a result these two temperatures may differ. When
the water heater is not in use for longer periods of time, it should be protected from
freezing by setting the temperature to " ". Do not disconnect the power. Thus the
temperature of water is maintained at about 10 °C. Should you choose to disconnect
the power, the water heater should be thoroughly drained before the onset of freezing
conditions. Water from the heater is drained through the inlet pipe of the heater. For
Legend:
1 - Connection terminal
2 - Thermostat and
bipolar thermal cut-out
3 - Electric heating element
4 - Pilot lamp
L - Live conductor
N - Neutral conductor
- Earthing conductor
230 V~
L
N
3
2
Electric installation
Summary of Contents for TGR 50-100 XNGU
Page 1: ...TGR 50 100 XNGU...
Page 2: ...2...
Page 25: ...MK 25 8 0 6 6 0 9 9 1 0 MPa 10 0 1 1 130 C...
Page 26: ...26 MK IEC 60364 7 701 VDE 0100 Teil 701 8...
Page 27: ...MK 27 0 1 1 A B C TGR 50 X 570 405 145 TGR 80 X 775 605 150 TGR 100 X 935 755 160...
Page 28: ...28 MK 3 1 7 5 3 5 4 6 3 2 8 1 2 3 4 5 6 7 8 H T...
Page 29: ...MK 29 1 5 2 H05VV F 3G 1 5 2 10 C 65 C 5 C 0 C eco 55 C 1 2 3 4 L N 230 V L N 3 2...
Page 30: ...30 MK 10 C...
Page 32: ...03 2016 498087...