35
EN
(*) Heating of water to 55 °C at inlet air temperature of 15 °C, 74% humidity and inlet temperature of water of
10 °C; in accordance with the EN16147 standard.
(**) Heating of water to 55 °C at inlet air temperature of 7 °C, 89% humidity and inlet temperature of water of
10 °C; in accordance with the EN16147 standard.
WE RESERVE THE RIGHT TO ANY MODIFICATIONS NOT AFFECTING THE
FUNCTIONALITY OF THE APPLIANCE.
Type
TC 80 ZNT
TC 100 ZNT
TC 120 ZNT
*Heating time A15 / W10-55
[h:min]
4:40
5:40
6:40
*Energy consumption in the selected cycle
of emissions A15 / W10-55
[kWh]
2,04
2,05
2,08
*COP
DHW
in the selected cycle of emissions
A15 / W10-55
3,10
3,10
3,10
**Heating time A7 / W10-55
[h:min]
5:20
6:50
8:41
**Energy consumption in the selected cycle
of emissions A7 / W10-55
[kWh]
2,45
2,35
2,51
**COP
DHW
in the selected cycle of emissions
A7 / W10-55
2,65
2,63
2,61
Power in standby mode
according to EN16147
[W]
19
20
27
Sound power / Sound pressure at 1m [dB(A)]
51 / 39,5
Air connections
[mm/m]
ø125 (
□
150x70) / 10
Working Air Flow
[m
3
/h]
100-230
Max acceptable pressure drop in the pipeline
(volumetric flow rate of air 150 m
3
/h)
[Pa]
90