Setting the temperature
Press field no.
5
(the set temperature starts blinking).
By pressing
+
or
–
you can change the temperature setting from 10 °C to 75 °C
(preset to economic temperature of 55 °C).
The setting is stored by pressing field no.
5
again, or when field no.
5
stops
flashing. After a few seconds, the display shows the actual temperature.
In case of power failure, the last stored value is restored.
Switching on the "TURBO" mode
If you need more warm water than the heat pump can heat up in a short period of
time, press field no.
13
(switches on the "TURBO" mode). The heat pump and
heater work simultaneously. The screen shows symbols no.
14
,
16
in
20
. When the
temperature reaches 55 °C the heat pump returns to the mode used before the
"TURBO" mode.
Switching on the "HOT" mode
If you want to heat the water to the maximum temperature of 75 °C, press field no.
15
. The heat pump will heat water to 55 °C. The screen displays symbols no.
16
in
20
. When the temperature in the boiler reaches 55 °C the electric heater turns on to
heat the temperature up to 75 °C. The screen displays the symbol no.
14
. When the
temperature reaches 75 °C the heat pump returns to the mode used before the
"HOT" mode.
Display of the quantity of water in the heat pump
Field no. 18 shows the following symbol:
- no warm water
- low quantity of warm water
- high quantity of warm water
Setting the vacation mode
In the vacation mode, you can set the number of days (maximally 100), when the
heat pump shall maintain the minimal temperature of water (approximately 10 °C).
Hold field no.
6
for a while (fields
5
and
6
start to flash).
By pressing fields
+
or
–
you can set the number of vacation days shown in field no.
5
.
By pressing field no.
6
again, or when field no.
6
stops flashing, the set number of
days is stored.
If you set the value to 0, then the heat pump will resume its normal operating mode
after confirming the setting, and illumination of field no.
6
will turn off.
After the set number of days has elapsed, the heat pump returns to the normal
mode and illumination of field no.
6
turns off.
Setting the TIMER mode
In the TIMER operating mode, you can set the times when the heat pump will start
and stop. For each timer combination you can set up to three time periods in which
the heat pump will not heat the water.