309655
B Lower kitchen cabinet with an oven
• Installing the oven under an induction hob is possible with
oven types EVP4.., EVP2.., which are
fi
tted with a cooling
fan. Before installing the oven, the rear wall of the kitchen
cabinet should be removed. Furthermore, a minimum of 6 mm
clearance should be provided at the front side, along the entire
width of the cabinet.
Common connection:
• 3 phase and 1 zero connection (3 1N, 400 V~/ 50 Hz):
- The voltage between the phases and the zeros is
230 V~. The voltage between the two phases is
400 V~. Fit a connecting bridge between connecting points
4-5. Phase 3 carries no load. The groups must have fuses
of at least 16 A (3x). The core diameter of the connecting
cable must be at least 2.5 mm
2
.
• 2 phase and 2 zero connection (2 2N, 230 V~ / 50 Hz):
- The voltage between the phases and the zeros is 230 V~.
- The group must have fuses of at least 16 A (2x). The core
diameter of the connecting cable must be at least 2.5 mm2.
Electrical connection
29