Instructions for use and installation
15
Beginning of operation
Start using the appliance in accordance with the instructions
for use.
Lit up all burners and check the stability of the flame with high
and low setting. Adjust air intake if necessary.
After that, take time and explain the operation and control of
the appliance to the user and read with him the instructions for
use.
Liquefield gas connection
9
Pipe coupling liquefied
10
Gasket
11
Connection R1/2
Nozzle specifications
Type of gas,
pressure
Auxiliary burner
Normal burner
Large burner
Triple burner
Oven burner
Infra-
red
burner
Standard
Fast
Wobe number
max
min
max
min
max
min
max
min
max
min
max
min
Natural gas H
Wo=45,7
÷
54,7
MJ/ m3,
Nominal heat
input (kW)
1
0,36
1
0,36
1,90
0,46
3
0,76
3,5
1,56
3,5
0,81
2,7
Natural gas E ,
Natural gas E+
Consumption
(l/h)
95,21
34,4
95,21
34,4
180,9
43,8
285,64
72,4
333,2
148,5
339
77,1
259
Wo=40,9
÷
54,7
MJ/m3
Nozzle mark
(1/100mm)
77
78
104
129
140
135
120
G20,
p=20mbar
Nozzle code
162081
162082
162083
162084
162085
609288
609287
Liquid gas 3+,
3B/P
Nominal heat
input (kW)
1
0,36
1
0,36
1,90
0,46
3
0,76
3,5
1,56
3,5
0,81
2,7
Wo=72,9
÷
87,3M
J/m3
Consumption
(g/h)
71,7
26,2
71,7
26,2
138,1
33,4
215,0
55,3
254,5
113,4
250,9
58,9
193,5
G30
Nozzle mark
(1/100mm)
50
29/24
50
29/24
69
33/26
87
43/33
93
57/57
90
42/42
81
p=30 mbar
Nozzle code
162162
162162
162164
162165
162166
609290
609289
•
Built-in regulation bolts on gas taps are originally set up for natural gas (municipal main gas supply). In case of modification of the
appliance to liquefied gas the regulation bolts need to be set up to achieve the required gas flow (to screw them down to tightened
position).
Nozzle code for minimum varies with different manufacturers. First digit from the pair represents IMIT, and the second one
COPRECI.
Burner heating input is indicated according to the maximum caloric value of gas Hs.
Warning: this work may be performed only by qualified expert, authorized by the gas distribution company or by the
authorized service!
Conversion to another type of gas
•
For the conversion procedure the appliance need not be
pulled out from its location.
•
Before starting to work on conversion, disconnect the
appliance from the mains.
•
Replace the existing nozzles of declared nominal heat input
with adequate nozzles for the new type of gas (see table).
•
Adjust the nozzle for the minimum heat input rate as long as
it requires to arrive at the minimum heat input.
•
Never unscrew nozzles for minimum heat input rate for more
than 1,5 turn.
•
Set the primary air of the oven burner and the infrared
burner.
Setting elements
Elements for regulation of cooking burners are accessible
when the control panel is removed, while the elements for
regulation of oven and infrared burner are exposed when both
the control panel and burners are removed.
•
Remove the cooktop grid and burner crowns with caps.
•
Remove the control buttons.
•
Unscrew bottom tightening screws from the control panel
and remove the panel.
Cooking zone burner (fig. 1 )
1
1
Burner crown cap
2
Burner crown with
burner cap support
3
Thermal probe
4
Ignition plug
5
Nozzle
Triple-ring burner (fig. 2)
5
nozzles
2