Temperature-controlled gas tap
D
Minimum heat load regulation screw
D
Infrared burner controls
To access the parts required to adjust the
oven burner to another type of gas, the
infrared heater has to be disassembled
(undo the screw on the front part of
the burner and pull it slightly forward).
To access the infrared burner nozzle,
disassemble the shutter.
1
Nozzle
2
Shutter
3
Burner
1 2
3
Air shutter settings are given in the table below.
G20/20mbar
G25/25mbar
G20/25mbar
G20/13mbar
G30/30mbar
G30/50mbar
Oven burner*
a = 5mm
(b = 50mm)
a = 2,5mm
(b = 47,5mm)
a = 7mm
(b = 52mm)
a = 3mm
(b = 48mm)
Infrared burner
a = 4mm
(b = 49mm)
a = 7mm
(b = 52mm)
a = 7mm
(b = 52mm)
a = 3mm
(b = 48mm)
For more primary air rotate the shutter to the left; for less primary air rotate the shutter
to the right.
G30/37mbar
G2.350/13mbar
G27/20mbar
G25/20mbar
G25.1/25mbar
G110/8mbar
G120/8mbar
Oven burner*
a = 7mm
(b = 52mm)
a = 2mm
(b = 47,5mm)
a = 1,5mm
(b = 46,5mm)
a = 5mm
(b = 50mm)
Infrared burner
a = 7mm
(b = 52mm)
a = 2mm
(b = 47mm)
a = 2mm
(b = 47,5mm)
a = 4mm
(b = 49mm)
For more primary air rotate the shutter to the left; for less primary air rotate the shutter
to the right.
*) Amount of primary air is correctly set when the flame is stable and the blue and green
flame core is clearly visible (somewhat less with liquefied natural gas). Distances "a" or "b"
are approximate.