137815
• Induction hob may be built into the 30 to 50 mm thick worktops.
• Bottom kitchen element must not have a drawer. It must be
fi
tted with a horizontal plate 140 mm away from the worktop
bottom surface. Space between the plate and the hob must be
empty and no objects may be stored or kept there.
• Rear side of the kitchen element must also have a 140 mm
high opening along the entire width of the element, and the
front part must have an opening of no less than 6 mm.
• Incorporation of the oven under the induction hob is
permissible for all
EVP4…, oven types, equipped with a
cooling fan
. Prior inserting the oven, it is necessary to remove
the rear kitchen element panel in the area of the oven opening.
Equally, the front part of the element must have an opening of
no less than 6 mm.
• Worktop must be placed absolutely horizontal.
• Suitably protect the edges of the cut aperture.
• By means of the supplied screws 4 fasten the supplied
tightening brackets 4 fasten to the front and the rear side of
the cooking hob and to the prepared aperture.
• Connect the cooking hob to the mains power supply (see
instructions for the connection of the cooking hob to mains
power supply).
• Insert the hob into the cut aperture.
• Press the hob
fi
rmly towards the worktop from above.
• For screwing down the
fi
xing clip it is not allowed to use
screws longer than 6,5 mm.
Installation procedure
Installation procedure
• Connections may be carried out by a quali
fi
ed technician
only. The earthing protection must comply with the standing
regulations.
• Connection terminals are revealed when the connection box
cover is removed.
• Prior any attempted connection check that the voltage
indicated on the rating plate is in line with your home power
supply.
• The rating plate is located underneath the appliance.
• The appliance is manufactured for use with the power supply
voltage AC 230 V.
• The electric wiring should be equipped with a circuit breaker
able to isolate the appliance from the mains in all points,
with the distance between terminals of at least 3 mm in
36
Connection to the power supplay
Summary of Contents for EIT 2600 P2
Page 19: ......