Gorenje Classico K57CLB1 Instructions For Use Manual Download Page 10

EN                                                                                                                                                          9 

IMPORTANT PRECAUTION 

In  case  of  left  side  connection  (seen  from  the  front) 
the  hose  must  be  connected  by  means  of  a  clamp 
fixed  in  the  back  cover  opening.  You  will  find  the 
fixing clamp in the accessory kit. 
 

CONNECTION TO THE NATURAL GAS 
NETWORK 

Connection  must  be  made  in  accordance  with 
standing  local  regulations.  In  case  of  excessive  gas 
pressure use pressure regulator. 

 

CONNECTION TO THE LPG NETWORK   

Special  LPG  coupling  must  be  installed  at  the  1/2" 
pipe connection. 

 

 

 

 
1. Connection ending 
2. Knee 
3. Connection hose (connection from the right) 
4. Connection hose (connection from the left) 
5. Fixing clamp 
6. Back cover of the cooker 

 

IMPORTANT PRECAUTION 

In  case  of  left  side  connection  (seen  from  the  front) 
the  hose  must  be  connected  by  means  of  a  clamp 
fixed  in  the  back  cover  opening.  You  will  find  the 
fixing clamp in the accessory kit. 

 

CONNECTION TO THE MAINS POWER

 

 
NOTE 

The  combined  cooker  is  a  Class  I  appliance 
according  to  the  electric  shock  prevention  degree 
and must be connected to the earthed mains power 
installation. The connections must  be  carried out by 
qualified personnel only. 

  The  appliance  is  fitted  with  power  cord  plug  for 

connection to the mains. 

  For  appliances  exceeding  2  kW  of  power  it  is 

recommended to use extra feed circuit with a 16A 
circuit breaker. 

  Power socket to which the appliance is connected 

must be accessible at all times. 

  Faulty  power  cord  must  be  immediately  replaced 

with a new one. 

 

CAUTION  

Make  sure  that  the  power  cord  is  installed  in  such 
way  to  avoid  touching  hot  parts  of  the  cooker 
(exhaust  at  the  back  side,  bottom  part  of  the  hob). 
High  temperature  could  cause  damage  to  the 
insulation. 

 

BURNER SETTINGS 

 

MINIMUM OUTPUT ADJUSTMENT 

Before starting any adjustments disconnect the 
appliance from the mains power supply. 
Adjustments must be carried out with the tap at the 
"SAVING" position. 
The minimum gas output is correctly adjusted when 
the inner cone of the flame arrives at the height of 3 
to 4 mm. 
If this is not the case, first remove the tap knob and 
then tighten or loosen the screw C, depending on 
whether the flame is to be reduced or increased. 
For butane/propane the screw C must be fully 
screwed in. 

 

 

Burner 

Small 

Medium 

Rapid 

Input power (kW)

 

1,0 

1,75 

2,7 

Natural gas  G 20 

– 20 mbar

 

Nozzle 

diameter 

(mm) 

0,77 

1,01 

1,22 

Natural gas  G 20 

– 13 mbar

 

Nozzle diameter 
(mm) 

0,83 

1,12 

1,37 

Propane-butane  G 30 

– 30 mbar

 

Nozzle diameter 
(mm) 

0,50 

0,66 

0,83 

Nominal flow (gram 
/ hour) 

72,8 

127,3 

196,5 

 

 

CONVERSION TO ANOTHER  

TYPE OF GAS 

 
Conversion of cooker  to another type  of gas can  be 
performed only by qualified technician.  

Adhere to the following procedure:  

  Change nozzles of all burners. 

  Adjust  or  change  gas  pressure  regulator  if 

installed. 

  Adjust SAVING power position of hob.  

  Stick  new  gas  setting  label  with  relevant  nozzle 

information. 

  To  conduct  this  operation,  make  the  appropriate 

entry in "The warranty card." 

Summary of Contents for Classico K57CLB1

Page 1: ......

Page 2: ...cases the appliance may be used only after the cause of such gas escape is discovered and removed by qualified personnel and the room thoroughly ventilated When using gas for cooking heat and moistur...

Page 3: ...nstructions and national decrees Before first use we must clean appliance and accessories After drying cleaned surfaces switch on main switch and keep following instructions Warning Do not clean and d...

Page 4: ...rill element inside of the oven The lower heating element is situated under the oven bottom In the rear part of the oven under the distributing cover the circular heating element and the ventilator ar...

Page 5: ...r Aqua Clean Heat is applied only by the bottom side of the oven Use this option for browning the bottom side of the food baking heavy moist pastry with fruit dressing The temperature selection button...

Page 6: ...by consecutively pressing the A knob until the symbol starts to flash Rotate the A knob to set stop time Confirm the setting by pressing the A knob again Clock hands will move to time display The ove...

Page 7: ...uctions WARNING The above surfaces should never come into contact with oven cleaning sprays as these will permanently damage the aluminum parts COOKER SURFACE Use a damp sponge with detergent for clea...

Page 8: ...crew the lamp glass cover in the oven by turning left Unscrew the faulty bulb Put and screw a new bulb in Mount the bulb glass cover NOTE For illumination it is necessary to use a bulb T 300 C E14 230...

Page 9: ...d their adjustment oven burner prime air saving power input thermoelectric sensors Explain to the customer all functions of the appliance and particulars regarding its servicing and maintenance LOCATI...

Page 10: ...nnected must be accessible at all times Faulty power cord must be immediately replaced with a new one CAUTION Make sure that the power cord is installed in such way to avoid touching hot parts of the...

Page 11: ...anufacturer reserves the right to make minor changes in the Instructions for Use resulting from relevant technological modifications or improvements of the product TECHNICAL DATA COMBINED ELECTRIC AND...

Page 12: ...CLI1 K57CLB1 A More efficient B C D E F G Less efficient A Energy consuption kWh 0 79 Time to cook standard load min 53 1 Energy consuption kWh 0 78 Time to cook standard load min 43 4 Usable volume l...

Page 13: ......

Reviews: