Wok
BG7xA/B /
BG9xA/B
Wok
BG6xB/E /
BG7xC/D /
BG9xD/E
Modification
P mbar
Gas type
nozzle
nozzle
150
142
-
20 / 25
G20
Convert from G20 - 20 mbar to:
170
155
Replace nozzle & no action
bypass
13
G20
100
94
Replace nozzle & screw in by-
pass (see 3A)
28-30/37
G30/G31
94
94
Replace nozzle & screw in by-
pass (see 3A)
37
(PL)
G30/G31
90
82
Replace nozzle & screw in by-
pass (see 3A)
50
G30/G31
Wok
Wok
Modification
P mbar
Gas type
BG7xA/B / BG9xA/B
BG6xB/E /
BG7xC/D /
BG9xD/E
nozzle
nozzle
100
94
-
28-30/37
G30/G31
Convert from G30/G31 - 28-30/37 mbar to:
150 (not for G20 25
mbar)
142
Replace nozzle &
adjust bypass (see
3C)
20 / 25
G20
Power table (kW-g/h):
PL G30/G31 - 37 mbar
G20 - 13 mbar
1.15 / 83
1.05
Auxiliary burner
1.95 / 140
1.95
Semi-rapid burner
3.30 / 238
3.10
Rapid burner
3.90 / 281
3.45
Wok burner
(BG6xB/E-BG7xC/D-
BG9xD/E)
3.90 / 281
4.00
Wok burner
(BG7xA/B - BG9xA/B)
Contents of conversion set
•
Nozzles for burners and (if applicable) by-pass screws for gas taps.
•
Data label with the modified gas specifications and setting.
24