background image

TAIYO ELECTRIC IND.CO.,LTD.

10

TAIYO ELECTRIC IND.CO.,LTD.

1

2

3

Key Operation

TEMP Display

NOTE ) If nothing is pressed for 30 seconds the temperature automatically returns to 

the temperature setting before it was changed. The tip temperature will remain 
unchanged.

*The set temperature should be set at 50°C (90˚F) higher than the sleep 

temperature (see the section 4-4), otherwise you will not be able to set the set 
temperature value. (Example: If the set temperature is set at 200°C (392˚F), 
the sleep temperature must be 150°C (302˚F) or lower.

  4-1  Changing the Set Temperature

Displays flashes

Refer to the Parameters table (on 

page 31) for the explanation of the display 

messages.

Press the

key.

Setting completed

Press the

Press  and hold the

key until the 

display shows 

340

.

key.

Example: Changing the temperature from 250°C (482

°F

) to 340°C (644

°F

).

When the station is shipped the temperature is set at 250°C (482°F). The temperature 
can be set from 50°C (122°F) to 450°C (842°F). 

*For the steps given in the operation instructions, only °C is used.

4

  Operating Instructions

Summary of Contents for RX-892AS

Page 1: ...ded you will enjoy years of safe reliable service Thank you again for buying a goot soldering station WARNING Before using the soldering station read the Operation Manual Failure to follow the safety...

Page 2: ...ry CAUTION Failure to obey a safety caution may result in a minor or moderate injury to yourself or to others Always follow the safety precautions to reduce the risk of electric shock fire or personal...

Page 3: ...25 5 1 How to Change the Tip 26 5 2 How to change the Fuse 27 5 3 How to change the Filter 27 5 4 Housing Cleaning 28 5 5 How to Use and Maintain a Lead Free Soldering Iron 28 6 Troubleshooting 29 7 R...

Page 4: ...release PAT Sleep mode can be exited by touching touch ing the wet sponge with the tip to cause tem perature fluctuation Effective when sleep setting temperature is greater than or equal to 100 C 7 Al...

Page 5: ...ms are missing or damaged please contact your goot distributor Please store the packaging for future shipment or repair 2 2 Unpacking For how to use please see p 32 Control Unit Operation Manual Repla...

Page 6: ...xing the tip If you do not perform this operation a measurement error occurs between the tip temperature and the set temperature CAUTION Operation Panel Filter Output Terminal for Soldering Unit Power...

Page 7: ...shes when the tip temperature is out of the upper and lower temperature limits 5 KEY LOCK lamp Flashes while setting the Key Lock function Lights up when the Key Lock mode is set 6 KEY LOCK key Used t...

Page 8: ...be soldered and melted solder get very hot Please be sure to wear proper apparel safety glass and gloves to prevent injury and property damage Do not wear unsuitable apparel for operation 5 CONNECT TO...

Page 9: ...not used the plastic parts adapter ring and or soldering unit housing of the soldering iron unit could be damaged Position the soldering iron stand on a flat work surface bench 9 CONCERNING THE TIP A...

Page 10: ...If the set temperature is set at 200 C 392 F the sleep temperature must be 150 C 302 F or lower 4 1 Changing the Set Temperature Displays flashes Refer to the Parameters table on page 31 for the expla...

Page 11: ...the Tip Temperature Displays alternately Tip No List Press the key so that the tip Setting completed Press and hold the key for over L2 is displayed Displays alternately 3 seconds continuously Press a...

Page 12: ...to contact with the RX 892AS soldering tip the metallic parts in the thermometer conduct heat which transfers away from the RX 892AS tip This results in the thermometer indicating a slightly lower tem...

Page 13: ...e key for over 3 seconds continuously changes to 150 While setting the sleep function the sleep lamp will flash The flashing of the sleep lamp will become faster 30 seconds before entering Sleep mode...

Page 14: ...rn off Set to 5 minutes before shipping Example Changing the sleep start time from 5 to 10 minutes Displays alternately Displays alternately Displays alternately Returns to the set temperature display...

Page 15: ...e key for over 3 seconds continuously Displays alternately Displays alternately Displays alternately NOTE If the sleep sensitivity value DIF is set too high there is a possibility that the sleep funct...

Page 16: ...P Display 3 When the SUT Shutdown Start Time value is set to 0 the shutdown function is OFF When the unit enters shutdown the Sdn and the temperature are displayed alternately After the temperature dr...

Page 17: ...nd hold the key for over 3 seconds continuously Setting completed Returns to the set temperature display Press the Press the key 6 times to display At key Setting the soldering start time Tip temperat...

Page 18: ...emperature Limit Upper Temperature Limit This function indicates to the operator with the sound of the alarm when the tip temperature goes past the set parameter The illustration on the right shows wh...

Page 19: ...her than the set temperature depending on the tip type or the kind of work Overshoot Overshoot can be controlled by setting the parameters 4 Press down the SET key for over 3 seconds 3 Press the UP ke...

Page 20: ...eration TEMP Display 4 9 Setting the Alarm Sound 3 Setting completed Returns to the set temperature display Press and hold the key for over 3 seconds continuously Press the key ten times Press the key...

Page 21: ...peration TEMP Display 3 Press and hold the key for over 3 seconds continuously Displays alternately Press the key to change the format to F Fahrenheit F Press the key to change the format to C Celsius...

Page 22: ...sing any three digit number from 001 to 999 l When the code number is set correctly the number will flash 5 times l If an incorrect code number is input the display will show NG and return to the init...

Page 23: ...ress the key Press and hold the Example When changing the code number from 123 to 234 for over 3 seconds continuously Press the keys so that the present code number is displayed Press the key Input th...

Page 24: ...ge temperature and or parameter settings Please keep this manual with authorized personnel only and in a safe place for future reference Resetting the Code Number 1 4 Key Operation TEMP Display 3 2 Pr...

Page 25: ...rsonnel only and in a safe place for future reference How to Restore Default Settings Setting completed The preset temperature is displayed Though the key lock can be released by doing the procedure s...

Page 26: ...the old tip 3 Insert a new tip aligned with the slit on the flange Push the tip as far as it will go and fix it securely with the tip fixing screw 5 1 How to Change the Tip NOTE When changing to a dif...

Page 27: ...to remove it A spare fuse is stored on the other side of the fuse box Therefore turn the fuse box over or to the side to replace the fuse 5 2 How to Change the Fuse Pull out with a slotted screwdrive...

Page 28: ...ompleted tin the tip with solder before turning the power off This protects the tip from oxidation when it starts heating up the next time it is in use A lead free soldering iron is more susceptible t...

Page 29: ...does not go ON Check that the power cord is plugged in Check that the fuse is not blown The soldering iron tip does not heat up Check that the heater is not damaged Error message Cause Countermeasure...

Page 30: ...tand ST 29 For RX 892AS 4 Sponge ST 53SP For ST 22 5 Brass Wool ST 40BW Cleaner For ST 22 2pcs set RX 89HRT series For replacement parts contact a goot distributor ST 53SP ST 40BW RX 89HRT 10D RX 89HR...

Page 31: ...emperature Calibration cAL C F 50 to 50 90 to 90 0 Sleep Set Temp SSt C F 0 to Pt 50 32 to Pt 90 200 Sleep Timer ct Minute 0 00 to 999 5 Sleep Sensitivity diF C F 0 to 20 0 0 to 36 0 2 0 Shutdown Star...

Page 32: ...revent fire or personal injury be sure that the stand has cooled sufficiently before storing it Rub the soldering iron tip on the moistened sponge Use the hole of the sponge for better cleaning Altern...

Page 33: ...TAIYO ELECTRIC IND CO LTD 33...

Page 34: ...TAIYO ELECTRIC IND CO LTD 34...

Page 35: ...TAIYO ELECTRIC IND CO LTD 35...

Page 36: ...RIES TAIYO ELECTRIC IND CO LTD Customer service Contact your nearest distributor goot is registered trade mark of TAIYO ELECTRIC IND CO LTD Printed in Japan JANUARY 2017 A1290AY00 AOB HomePage www goo...