
The inverter can exclude the possibility of DC residual currents to 6mA in the system,Where an external RCD is required in addition
to the built-in RCMU, type A RCD must be used to avoid tripping
。
The default photovoltaic module is not grounded.
CE Mark
Signals danger due to electrical
shock and indicates the time (5
minutes) to allow after the
inverter has been turned off and
disconnected to ensure safety in
any installation operation.
Refer to the operating instructions
If there are more than 3 PV strings on input side, an additional fuse installing will be suggested.
Caution! - Failure to observe a warning
indicated in this manual may result in minor
or moderate injury.
Danger of high voltage and electric shock!
Danger of hot surface!
Product should not be disposed as normal
household waste.
Components of the product can be recycled.
This side up - The package must always be
transported, handled and stored in such a
way that
the arrows always point upwards.
No more than six (6) identical packages be
stacked on each other.
The package/product should be handled
carefully and never be tipped over or
slung.
Keep Dry – The package/product must be
protected from excessive humidity and
must accordingly be stored under cover.
1 Symbols
2
Safety
and
Warning
To avoid electric shock, must be terminated AC out put of inverter then terminated DC input disconnected and wait at least 5
minutes before performing any installation or maintenance.
O
The temperature of some parts of the inverter may exceed 60C during operation. To avoid being burnt, do not touch the inverter
during operation. Let it cool before touching it.
Keep children away from the inverter.
Without permission, open the front cover of the inverter is not allowed. Users should not touch/replace any of the components
except for the DC/AC connectors. GOODWE will not bear any consequences caused by unauthorized actions which will lead to
potential injury to people and damage to inverters.
Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to theinverter;
otherwise the inverter may be damaged and the warranty will be annulled.
●
●
●
●
●
●
Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the
inverter may be damaged and the warranty will be annulled.
●
When exposed to sunlight, the PV array will generate very high voltage which will cause potential danger to people. Please strictly
follow the instruction we provided.
●
PV modules should have an IEC61730 class A rating.
●
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be
impaired.
●
Completely isolate the equipment should
:
switch off the DC switch, disconnect the DC terminal, and disconnect the AC terminal or
AC breaker.
●
Prohibit inserting or pulling the AC and DC terminals when the inverter is working.
●
Only DC connectors provided by GoodWe are permitted to use, otherwise the
inverter
may
be
damaged
and
the
warranty will be
annulled.
●
Person could access to inverter status through mobile phone and computer display please refers to chapter 3.4.4 and 3.4.5.
and
error code could be shown not only on inverter LCD display
but also mobile phone APP interface.
3
Installation
3.1 Mounting Instruction
●
In order to achieve optimal performance, the ambient temperature should be kept lower than 45 °C.
●
For the convenience of checking the LCD display and possible maintenance activities, please install the inverter at eye level.
●
Inverters should NOT be installed near inflammable or explosive items. Any strong electro-magnetic equipment should be kept
away from installation site.
●
Product label and warning symbol shall be clear to read after installation.
●
Please do not install inverter under direct sunlight, rain and snow.
Direct
Sunlight
Rain
Exposure
Snow
Lay
up
3
.
2
Overview and Packaging
After opening the package, confirm if it is consistent with specification of inverter you purchased
.
Smart DT (hereinafter referred to as SDT) series inverter of Jiangsu GoodWe Power Supply Technology Co.,Ltd. ( hereinafter
referred to as GoodWe ) strictly conforms to related safety rules in design and test. As electric and electronic equipment, Safety
Regulation shall be followed during installation and maintenance. Improper operation may bring severe damage to the operator, the
third party and other properties. SDT: Smart Dual-MPPT, Three-Phase).
●
,
,
(
Installation maintenance and connection of inverters must be performed by qualified personnel,in compliance with local electrical
standards regulations and there quire ments of local power authorities and /or companies.
Summary of Contents for GW10KN-DT
Page 15: ...8 Certificates 25...