The inverter can exclude the possibility of DC residual currents to 6mA in the system,Where an external RCD is required in addition 

to the built-in RCMU,  type A RCD must be used to avoid tripping

The default photovoltaic module is not grounded.

CE Mark

Signals danger due to electrical 
shock and indicates the time (5
minutes) to allow after the 

inverter has been turned off and 
disconnected to ensure safety in 
any installation operation.

Refer to the operating instructions

If there are more than 3 PV strings on input side, an additional fuse installing will be suggested.

Caution! - Failure to observe a warning 
indicated in this manual may result in minor 
or moderate injury.

Danger of high voltage and electric shock!

Danger of hot surface!

Product should not be disposed as normal 
household waste.

Components of the product can be recycled.

This side up - The package must always be

 

transported, handled and stored in such a 
way that

 

the arrows always point upwards.

No more than six (6) identical packages be 
stacked on each other.

The package/product should be handled

 

carefully and never be tipped over or 
slung.

Keep Dry – The package/product must be 
protected from excessive humidity and 
must accordingly be stored under cover.

1 Symbols

2

  

Safety

 

and

 

Warning

To avoid electric shock, must be terminated AC out put of inverter then terminated DC input disconnected and wait at least 5 

minutes before performing any installation or maintenance.

O

The temperature of some parts of the inverter may exceed 60C during operation. To avoid being burnt, do not touch the inverter

during operation. Let it cool before touching it.

 Keep children away from the inverter.

Without permission, open the front cover of the inverter is not allowed. Users should not touch/replace any of the components 

except for the DC/AC connectors. GOODWE will not bear any consequences caused by unauthorized actions which will lead to 

potential injury to people and damage to inverters.

Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to theinverter; 

otherwise the inverter may be damaged and the warranty will be annulled.

 

 

   

 

 

 

 

 

 

 

Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the

 

inverter may be damaged and the warranty will be annulled.

 

   

 

 

 

When exposed to sunlight, the PV array will generate very high voltage which will cause potential danger to people. Please strictly 

follow the instruction we provided. 

PV modules should have an IEC61730 class A rating.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be

 

impaired.

Completely isolate the equipment should 

switch off the DC switch, disconnect the DC terminal, and disconnect the AC terminal or 

AC breaker.

Prohibit inserting or pulling the AC and DC terminals when the inverter is working.

Only DC connectors provided by GoodWe are permitted to use, otherwise the

 

inverter

 

may

 

be

 

damaged

 

and

 

the

 

warranty will be 

annulled.

Person could access to inverter status through mobile phone and computer display please refers to chapter 3.4.4 and 3.4.5.

 

and

 

error code could be shown not only on inverter LCD display

 

but also  mobile phone APP interface.

3

  

Installation

3.1 Mounting Instruction

● 

In order to achieve optimal performance, the ambient temperature should be kept lower than 45 °C.

● 

For the convenience of checking the LCD display and possible maintenance activities, please install the inverter at eye level. 

● 

Inverters should NOT be installed near inflammable or explosive items. Any strong electro-magnetic equipment should be kept 

away from installation site.

● 

Product label and warning symbol shall be clear to read after installation.

● 

Please do not install inverter under direct sunlight, rain and snow.

Direct

 

Sunlight

Rain

 

Exposure

Snow

 

Lay

 

up

3

.

2

 

Overview and Packaging

After opening the package, confirm if it is consistent with specification of inverter you purchased

.

Smart DT (hereinafter referred to as SDT) series inverter of Jiangsu GoodWe Power Supply Technology Co.,Ltd. ( hereinafter 

referred to as GoodWe ) strictly conforms to related safety rules in design and test. As electric and electronic equipment, Safety 

Regulation shall be followed during installation and maintenance. Improper operation may bring severe damage to the operator, the 

third party and other properties.  SDT: Smart Dual-MPPT, Three-Phase).

 

 

   

 

   

   

 

 

 

 

 

 

 

 

 

   

 

 

 

 

(

Installation maintenance and connection of inverters must be performed by qualified personnel,in compliance with local electrical 

standards regulations and there quire ments of local power authorities and /or companies.

Summary of Contents for GW10KN-DT

Page 1: ...goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is s...

Page 2: ...verview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Reload 4 5 Power limiting function setting 0...

Page 3: ...imum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty will be annulled When exposed to sunlight the PV array will generate very high voltage which will cause...

Page 4: ...tion Installation position should be selected based on the following aspects The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid su...

Page 5: ...Add breaker or fuse to AC side the specification should be more than 1 25 times of rated AC output current 3 The PE line of inverter should be connected to the earth make sure the impedance of neutral...

Page 6: ...risk of shock hazard if the requirement of minimum resistance is not met 5 Positive shall be red negative shall be black 3 4 2 AC circuit breaker and leakage current protection device In order to ensu...

Page 7: ...gateway cover with screwdriver Remove the screw cap of the cable gland Remove the one hole sealing ring Insert the gateway cable through the components as the followings screw cap one hole sealing ri...

Page 8: ...lation you need enable Power Limit function and set export power limiting value on LCD via button according to next chapter 4 2 3 4 7 Earth FauItAlarm Figure3 4 6 1 3 4 6 Power Limiting Device DRED In...

Page 9: ...012 01 18 Utility Loss 13 12 25 2012 03 25 Set Time 13 12 25 2012 03 25 Language English WiFi Reset Successful WiFi Reset Failed Year Mode Month Mode Day Mode Hour Mode Error Log Date Time Language Hi...

Page 10: ...area shows the maximum rated power generation each hour for inverter This area can display information in different modes There are 5 display modes in total real time mode hour mode day mode month mod...

Page 11: ...ENTER the chosen safety will be set If there is no EXACTLY proper country code please choose 50Hz Grid Default or 60Hz Grid Default accordingly the safety you This function is used for special requir...

Page 12: ...inputs from the PV generator and check the peripheral AC system 3 When the problem is cleared reconnect the PV panel and check the Inverter status 4 Contact local service office for help if the probl...

Page 13: ...40us 40A 40us 40A 40us 6 Technical Parameters and Block Diagram 6 1 Technical Parameters GW4000 DT GW5000 DT GW6000 DT GW8000 DT GW9000 DT GW10KN DT Operating Altitude m User Interface Communication S...

Page 14: ...with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans Disconnect the AC breaker firstly...

Page 15: ...8 Certificates 25...