Goodwe GW10KN-DT User Manual Download Page 13

Max.DC Input Power(W)

Max.DC Input voltage(V)

Start-up

MPPT Range for Full Load (V)

Nominal DC Input Voltage (V)

Max. Input Current (A)

Max. Short Current (A)

No.of MPP Trackers

No.of Input Strings per Tracker

PV String Input Data

Technical Data

Nominal Output Power (W)

Max. Output Apparent Power (VA)

Nominal Output Voltage (V)

Nominal Output Frequency(Hz)

Max. Output  Current (A)

Output  Power Factor

Output  THDi (@Nomina Output)

Europe efficiency

Anti-islanding Protection

Input Reverse Polarity Protection

Insulation Resistor Detection

Residual Current Monitoring Unit

Output Over Current Protection

Output Short Protection

5200

6500

7800

9600

10800

12000

1000

1000

1000

1000

1000

1000

200~800

200~800

200~800

200~850

200~850

200~850

620

620

620

620

620

620

11/11

11/11

11/11

11/11

11/11

11/11

180

180

180

180

180

180

195~800

240~800

285~800

380~850

430~850

480~850

13.8

13.8

13.8

13.8

13.8

13.8

2

2

2

2

2

2

1

1

1

1

1

1

4000

5000

6000

8000

9000

10000

4000

400,3L/N/PE

50/60

5000

6000

8000

9000

10000

400,3L/N/PE

400,3L/N/PE

400,3L/N/PE

400,3L/N/PE

400,3L/N/PE

50/60

50/60

50/60

50/60

50/60

8.5

8.5

10

12.1

13.6

15.2

~1(Adjustable from 0.8 leading to 0.8 lagging)

<2%

>97.5%

98.0%

98.3%

>98.0%

DC Backfeed Current

Over Voltage Category 

0

II

AC Backfeed Current

Over Voltage Category 

0

III

AFD

DC Overcurrent Protection(A)

AC Overcurrent Protection(A)

17

Current (inrush) a.c. A 

Maximum output fault 

current a.c. A (peak and duration) 

17

17

17

17

17

16

16

16

25

25

25

30A 40us

15A 2 s

u

15A 2 s

u

15A 2 s

u

15A 2 s

u

15A 2 s

u

15A 2 s

u

30A 40us

30A 40us

40A 40us

40A 40us

40A 40us

6 Technical Parameters and Block Diagram

6

.

1 Technical Parameters

GW4000-DT

GW5000-DT

GW6000-DT

GW8000-DT

GW9000-DT

GW10KN-DT

Operating Altitude(m

)

User

 

Interface

Communication

Size Width

*

Height

*

Depth

 

mm

(

)

Night self consumption(W)

4000

al

LCD&LED

VDE-AR-N 4105,VDE0126-1-1 EN50438(PL),EN50438(SW) G83,IEC61727,AS4777.2

IEC62116,EN50438(IR) ERDF-NOI-RES_13E

EN61000-6-1,EN61000-6-2,EN61000-6-3,EN61000-6-4

24

516*415*192

Technical Data

Moisture Location Category

4K4H

Environment category

Outdoor

Indoor

 

External Environment Pollution Degree

Grade1

2

3

Output Over Voltage Protection

Operating Temperature Range(

℃)

Weight(kg)

Protection

 

degree

Topology

IP65

0~100%

-25~60

GW4000-DT

GW5000-DT

GW6000-DT

GW8000-DT

GW9000-DT

GW10KN-DT

 

Zref :

SDT4~10KW: 

RA = 0.24  ; XA = j 0.15   at 50 Hz; RN = 0.16  ; XN = j 0.10   at 50 Hz.

Note

Overvoltage category definition

Category I: applies to equipment connected to a circuit where measures have been taken to reduce transient overvoltage to a

                  low level.

Category II: applies to equipment not permanently connected to the installation. Examples are appliances, portable tools and

                   other plug-connected equipment;

Category III: applies to fixed equipment downstream of and including, the main distribution board. Examples are switchgear and

                    other equipment in an industrial installation;

Category IV: applies to equipment permanently connected at the origin of an installation (upstream of the main distribution board)

                    Example are electricity meters, primary overcurrent protection equipment and other equipment connected directly to

                    outdoor open lines.

Moisture location category definition

● 

Noice emission of the inverter is up to civil standard, but not suitable for installtion inside or living quarters

.

Summary of Contents for GW10KN-DT

Page 1: ...goodwe com cn service au goodwe com cn GoodWe Australia www goodwe com cn service nl goodwe com cn GoodWe Netherlands GoodWe UK www goodwe co uk enquiries goodwe co uk Note The information above is s...

Page 2: ...verview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Reload 4 5 Power limiting function setting 0...

Page 3: ...imum rated input voltage of the inverter otherwise the inverter may be damaged and the warranty will be annulled When exposed to sunlight the PV array will generate very high voltage which will cause...

Page 4: ...tion Installation position should be selected based on the following aspects The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid su...

Page 5: ...Add breaker or fuse to AC side the specification should be more than 1 25 times of rated AC output current 3 The PE line of inverter should be connected to the earth make sure the impedance of neutral...

Page 6: ...risk of shock hazard if the requirement of minimum resistance is not met 5 Positive shall be red negative shall be black 3 4 2 AC circuit breaker and leakage current protection device In order to ensu...

Page 7: ...gateway cover with screwdriver Remove the screw cap of the cable gland Remove the one hole sealing ring Insert the gateway cable through the components as the followings screw cap one hole sealing ri...

Page 8: ...lation you need enable Power Limit function and set export power limiting value on LCD via button according to next chapter 4 2 3 4 7 Earth FauItAlarm Figure3 4 6 1 3 4 6 Power Limiting Device DRED In...

Page 9: ...012 01 18 Utility Loss 13 12 25 2012 03 25 Set Time 13 12 25 2012 03 25 Language English WiFi Reset Successful WiFi Reset Failed Year Mode Month Mode Day Mode Hour Mode Error Log Date Time Language Hi...

Page 10: ...area shows the maximum rated power generation each hour for inverter This area can display information in different modes There are 5 display modes in total real time mode hour mode day mode month mod...

Page 11: ...ENTER the chosen safety will be set If there is no EXACTLY proper country code please choose 50Hz Grid Default or 60Hz Grid Default accordingly the safety you This function is used for special requir...

Page 12: ...inputs from the PV generator and check the peripheral AC system 3 When the problem is cleared reconnect the PV panel and check the Inverter status 4 Contact local service office for help if the probl...

Page 13: ...40us 40A 40us 40A 40us 6 Technical Parameters and Block Diagram 6 1 Technical Parameters GW4000 DT GW5000 DT GW6000 DT GW8000 DT GW9000 DT GW10KN DT Operating Altitude m User Interface Communication S...

Page 14: ...with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans Disconnect the AC breaker firstly...

Page 15: ...8 Certificates 25...

Reviews: