Goodwe GW009K-DT User Manual Download Page 8

12

Normal

2012-03-26

Vp1=200.3V

Ip1= 15.8A

Vp2=300.8V

Ip2= 12.5A

VL1=230.5V
VL2=232.5V
VL3=233.0V

IL1=15.5A
IL2=15.3A
IL3=15.4A

F1=50.00HZ
F2=50.01HZ
F3=50.00HZ

Model

GW17K-DT

Ver:1.00

Error Log

Date&Time

Language

Histogram

Error Log

Date&Time

Language

Histogram

Error Log

Date&Time

Language

Histogram

Error Log

Date&Time

Language

Histogram

Error Log

Date&Time

Language

Histogram

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Set

 

Modbus

Shadow

 

OFF

Error Log

Date&Time

Language

Histogram

Over

Temperatur

13

:

29

:

25

2012

-

01

-

18

………

Utility

Loss

13

:

12

:

25

2012

-

03

-

25

Error Log

Date&Time

Language

Histogram

Set

 

Time

13

:

12

:

25

2012

-

03

-

25

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Set

 

Zigbee

WiFi Reset

WiFi Reload

100% Rated

Language

:

English

语言:

中文

Error Log

Date&Time

Language

Histogram

…………

WiFi

Reset

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

Enter

WiFi

Resetting

WiFi 

Successful

Reset

WiFi 

eset

 

R

Failed

Year

 

Mode

Month

 

Mode

Day

 

Mode

Hour

 

Mode

Error Log

Date&Time

Language

Histogram

Year

 

Mode

Month

 

Mode

Day

 

Mode

Hour

 

Mode

Year

 

Mode

Month

 

Mode

Day

 

Mode

Hour

 

Mode

Enter

Year

 

Mode

2012

Month

 

Mode

2012

Day

 

Mode

2012-03

Year

 

Mode

2012-03-26

Set

 

Modbus

Shadow

 

OFF

Set

 

Zigbee

WiFi Reset

WiFi Reload

70% Rated

WiFi

Reload

Enter

WiFi

Reloading

Set

 

Modbus

Shadow

 

OFF

Set Usual

ADDR:247

Shadow

 

OFF

Down

Set Usual

ADDR:247

Shadow

 

OFF

ADDR:

 

247

Enter

Enter

Year

 

Mode

Month

 

Mode

Day

 

Mode

Hour

 

Mode

Down

 

Or Up

Some

 

times

ADDR

:

100

Set Usual

ADDR

:

100

Shadow

 

OFF

WiFi Model

Enter

ESC

Down

Enter

WiFi 
eload

Success

R

WiFi

Reload
Failure

Set

 

Modbus

Shadow

 

OFF

Set

 

Modbus

Shadow

 

ON

Enter

Enter

Enter

Enter

*

*

Wait

Wait

Enter

Up

Down

Up

Up

Down

Up

Down

Down

Up

Up

Down

Up

Down

Up

Down

Down

Up

Down

Up

Up

Down

ESC

ESC

Up

Down

Up

Down

Up

Down

ESC

ESC

Up

Down

Up

Down

ESC

ESC

Up

Down

ESC

Up

Down

Up

Down

Up

Down

Up

Down

Up

Down

Up

Down

ESC

ESC

*For SDT series , LCD display as “Set Local”, not “Set Zigbee”

.

  

For SDT series, there is no “Set Modbus” and “Shadow OFF”

.

11

4.2 User Interface and Controls

LED lights in Yellow/Green/Red correspondently refer to POWER/RUN/FAULT.

Yellow: Light on indicates the inverter is electrified. 

To WiFi model inverters, If the Power light flashes every 0.5sec, it indicates the connection between inverter and your WiFi 

router is abnormal; If the Power light flashes every 2.5sec, it indicates the inverter has successfully connected to your WiFi 

router  however  connection  with  Web  Server  is  abnormal;  If  the  Power  light  keeps  on  continuously,  it  indicates  WiFi 

monitoring is all normal. 

Green:  If  the  RUN  light  keeps  on,  it  indicates  inverter  operating  normally.  If  the  RUN  light  is  flashing,  it  indicates  the  inverter  is 

undertaking self-checking. 

Red: If the Fault light keeps on, it indicates inverter abnormal conditions and require service. 

4 System Operation

4.1 LED Lights

POWER

RUN

FAULT

ESC

Up

Down

Enter

ESC

(

1)

 

The Figure of LCD display screen is shown as follow:

Area

 ①

Area

 ②

Area

 ③

Area

 ④

Display area is divided as follows:

KWh

P

M

W

KWh

N

ormal

2 0 1 4

-

0 4

-

0 3

18

6

4

8

10

12

14

16

KWh

Set Safety Country 

:

If display shows 'Configure Safety', then long press (2S) the key to enter the second level menu. Short press to browse the safety

 

country  list  available.  Choose  suitable  safety  country  according  to  the  location  of  installation.  The  inverter  will  store  the  chosen

 

safety country

 

after 20 seconds if no operation.

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter

 

long

 

press

Enter long press

(

2) Display area

Area

①——

Flow of Power Generated:

Area

① 

indicates the flow of energy. Full line 

(   )

between inverter and the grid means the grid is available but inverter is not yet

 

feeding 

power at the time. Flashing dashing lines

 (---) 

mean inverter is feeding power to grid. No line means grid is not available. Flashing dash 

lines between the sun, modules and inverter means there is energy from the sun to modules and then from modules to inverter. 

Area

②——

Status Information:

Area

 displays inverter power generation status. Different inverter status like languages & time settings, error logs, historical power 

information etc could all be switched and displayed here through button operations.

Area 2 has 3 levels of menu. Please refer to the diagram below.

Summary of Contents for GW009K-DT

Page 1: ...D Suzhou 215163 China T 86 512 6239 6771 service goodwe com cn www goodwe com cn GoodWe Australia 74 Tarana Avenue Glenroy VIC 3046 Australia T 61 3 9972 9938 australia goodwe com cn www goodwe de Goo...

Page 2: ...tificates 3 1 Mounting Instruction 3 2 Overview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Relo...

Page 3: ...should not touch replace any of the components except for the DC AC connectors GOODWE will not bear any consequences caused by unauthorized actions which will lead to potential injury to people and da...

Page 4: ...ts The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid surface Select a well ventilated place sheltered from direct sun radiation P...

Page 5: ...the impedance of neutral wire and earth wire less than 10 ohm 4 Disconnect the breaker or fuse between the inverter and the utility 5 Connect the inverter to the grid as follows Installation instructi...

Page 6: ...connector There are two types of DC connectors SUNCLIX and MC4 series Please refer to Figure 3 4 2 1 Installation instruction of SUNCLIX connectors please refer to Figure 3 4 2 2 SUNCLIX Series MC4 Se...

Page 7: ...terproof kit to inverter Fasten the screw cap of the cable gland Cables 3 4 5 WiFi Communication The WiFi communication function is only applied to WiFi models the detailed configuration instruction c...

Page 8: ...User Interface and Controls LED lights in Yellow Green Red correspondently refer to POWER RUN FAULT Yellow Light on indicates the inverter is electrified To WiFi model inverters If the Power light fla...

Page 9: ...ar mode display annual power generation for recent 10 years Take day mode for example 72kWh means the maximum power generation of recent 16 days The unit on the left corner sometimes turns to MWh from...

Page 10: ...Long press ENTER in the model type interface there will be set safety interface Press Down or Up to choose the safety you need and then long press ENTER the chosen safety will be set If there is no EX...

Page 11: ...s Vac Failure 1 The PV Inverter will automatically restart within 5 minutes if the grid returns to normal 2 Make sure grid voltage is in conformity with the specification 3 Contact local service offic...

Page 12: ...ng Ambient temperature range Relative humidity Moisture location category Max operating altitude Protection degree Environment category External environment pollution degree Topology Night power consu...

Page 13: ...ble tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are switchgear and other equipment in an industria...

Page 14: ...Fans DT series inverter is fitted with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans...

Page 15: ...I RES_13E 7 2 Checking the DC Switch DC switch does not require any maintenance It is recommended though not compulsory to Check the DC switch regularly Activate the DC switch 10 times in a row once a...