Goodwe GW009K-DT User Manual Download Page 3

Caution!  -  Failure  to  observe  a  warning 
indicated in this manual may result in minor 
or moderate injury.

Danger of high voltage and electric shock!

Danger of hot surface!

Product should not be disposed as normal 
household waste.

CE Mark

Components of the product can be recycled.

This side up - The package must always be

 

transported,  handled  and  stored  in  such  a 
way that

 

the arrows always point upwards.

No more than six (6) identical packages be 
stacked on each other.

The  package/product  should  be  handled

 

carefully  and  never  be  tipped  over  or 
slung.

Keep  Dry  – The  package/product  must  be 
protected  from  excessive  humidity  and 
must accordingly be stored under cover.

Signals danger due to electrical shock and indicates the time (5 minutes) to allow after the

 

inverter has been turned off and disconnected to ensure safety in any installation operation.

1 Symbols

DT/  Smart  DT  (hereinafter  referred  to  as  SDT)  series  inverter  of  Jiangsu  GoodWe  Power  Supply Technology  Co.,Ltd.  (  hereinafter 

referred  to  as  GoodWe  )  strictly  conforms  to  related  safety  rules  in  design  and  test. As  electric  and  electronic  equipment,  Safety 

Regulation shall be followed during installation and maintenance. Improper operation may bring severe damage to the operator, the 

third  party  and  other  properties. 

(

DT:  Dual-MPPT,  Three-Phase,  covering  09kW/10kW/12kW/15kW/17kW/20kW/25kW;  SDT:  Smart 

Dual-MPPT, Three-Phase, covering 4kW/5kW/6kW.)

Installation, maintenance and connection of inverters must be performed by qualified personnel, in compliance with local electrical

 

standards, regulations and the requirements of local power authorities and/or companies.

To  avoid  electric  shock,  DC  input  and  AC  output  of  the  inverter  must  be  terminated  at  least  5  minutes  before  performing  any

 

installation or maintenance.

O

The temperature of some parts of the inverter may exceed 60 C during operation. To avoid being burnt, do not touch the inverter

 

during operation. Let it cool before touching it.

 Keep children away from the inverter.

Without  permission,  open  the  front  cover  of  the  inverter  is  not  allowed.  Users  should  not  touch/replace  any  of  the  components 

except  for  the  DC/AC  connectors.  GOODWE  will  not  bear  any  consequences  caused  by  unauthorized  actions  which  will  lead  to 

potential injury to people and damage to inverters.

Static electricity may damage electronic components. Appropriate method must be adopted to prevent such damage to the

 

inverter; 

otherwise the inverter may be damaged and the warranty will be annulled.

Ensure the output voltage of the proposed PV array is lower than the maximum rated input voltage of the inverter; otherwise the

 

inverter

 

may

 

be

 

damaged

 

and

 

the

 

warranty will be annulled.

01

02

2

  

Safety

 

and

 

Warning

3

  

Installation

3.1 Mounting Instruction

● 

In order to achieve optimal performance, the ambient temperature should be kept lower than 45 °C.

● 

For the convenience of checking the LCD display and possible maintenance activities, please install the inverter at eye level. 

● 

Inverters  should  NOT  be  installed  near  inflammable  or  explosive  items. Any  strong  electro-magnetic  equipment  should  be  kept 

away from installation site.

● 

Product label and warning symbol shall be clear to read after installation.

● 

Please do not install inverter under direct sunlight, rain and snow.

3

.

2

 

Overview and Packaging

After opening the package, confirm if it is consistent with specification of inverter you purchased

.

3.2.1 Inverter Overview

③ ④

DT Series inverter illustration. 

1. PV input terminals
2. DC Switch (Optional)
3. USB port
4. RS485 port or 

   

WiFi antenna port

5. AC output terminal
6. LCD display
7. LED lights
8. Buttons

When

 

exposed

 

to

 

sunlight, the PV array will generate very high voltage which will cause potential danger to people. Please strictly 

follow the instruction we provided. 

PV modules should have an IEC61730 class A rating.

If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be

 

impaired.

Completely isolate the equipment should 

switch off the DC switch, disconnect the DC terminal, and disconnect the AC terminal

 

or AC breaker.

Prohibit inserting or pulling the AC and DC terminals when the inverter is working.

Person could access to inverter status through mobile phone and computer display please refers to chapter 3.4.4 and 3.4.5.

Direct

 

Sunlight

Rain

 

Exposure

Snow

 

Lay

 

up

Summary of Contents for GW009K-DT

Page 1: ...D Suzhou 215163 China T 86 512 6239 6771 service goodwe com cn www goodwe com cn GoodWe Australia 74 Tarana Avenue Glenroy VIC 3046 Australia T 61 3 9972 9938 australia goodwe com cn www goodwe de Goo...

Page 2: ...tificates 3 1 Mounting Instruction 3 2 Overview and Packaging 3 3 Inverter Installation 3 4 Electrical Connection 4 1 LED Lights 4 2 User Interface and Controls 4 3 Error Code 4 4 WiFi Reset WiFi Relo...

Page 3: ...should not touch replace any of the components except for the DC AC connectors GOODWE will not bear any consequences caused by unauthorized actions which will lead to potential injury to people and da...

Page 4: ...ts The installation method and mounting location must be suitable for the inverter s weight and dimensions Mount on a solid surface Select a well ventilated place sheltered from direct sun radiation P...

Page 5: ...the impedance of neutral wire and earth wire less than 10 ohm 4 Disconnect the breaker or fuse between the inverter and the utility 5 Connect the inverter to the grid as follows Installation instructi...

Page 6: ...connector There are two types of DC connectors SUNCLIX and MC4 series Please refer to Figure 3 4 2 1 Installation instruction of SUNCLIX connectors please refer to Figure 3 4 2 2 SUNCLIX Series MC4 Se...

Page 7: ...terproof kit to inverter Fasten the screw cap of the cable gland Cables 3 4 5 WiFi Communication The WiFi communication function is only applied to WiFi models the detailed configuration instruction c...

Page 8: ...User Interface and Controls LED lights in Yellow Green Red correspondently refer to POWER RUN FAULT Yellow Light on indicates the inverter is electrified To WiFi model inverters If the Power light fla...

Page 9: ...ar mode display annual power generation for recent 10 years Take day mode for example 72kWh means the maximum power generation of recent 16 days The unit on the left corner sometimes turns to MWh from...

Page 10: ...Long press ENTER in the model type interface there will be set safety interface Press Down or Up to choose the safety you need and then long press ENTER the chosen safety will be set If there is no EX...

Page 11: ...s Vac Failure 1 The PV Inverter will automatically restart within 5 minutes if the grid returns to normal 2 Make sure grid voltage is in conformity with the specification 3 Contact local service offic...

Page 12: ...ng Ambient temperature range Relative humidity Moisture location category Max operating altitude Protection degree Environment category External environment pollution degree Topology Night power consu...

Page 13: ...ble tools and other plug connected equipment Category III applies to fixed equipment downstream of and including the main distribution board Examples are switchgear and other equipment in an industria...

Page 14: ...Fans DT series inverter is fitted with two fans on its left side The fan intakes and handle covers should be cleaned yearly with a vacuum cleaner For more thorough cleaning completely remove the fans...

Page 15: ...I RES_13E 7 2 Checking the DC Switch DC switch does not require any maintenance It is recommended though not compulsory to Check the DC switch regularly Activate the DC switch 10 times in a row once a...