Section 5:
Operation
10
11
12
13
14
15
16
17
18
To retract the platens after pressing, push the control lever towards the machine.
Once the platen is fully retracted, place the directional control lever to the neutral position and rotate the power switch
counter-clockwise to de-energize the hydraulics.
Gently work the cake separator between the bag and the dry pomace cake on both sides of the cake on all layers. Be careful
not to wear the bottom and sides of the bags by forcefully jamming the cake separator into the bags.
Slide the juice tray out from underneath the racks so that you may turn the racks upside down to empty the pomace from
bags.
Place a catch container beneath the press area to catch the spent pomace.
Rotate the press area 180° and shake the bags to allow the cake to fall out.
Remove the catch container and dispose of the spent pomace.
Rotate the press area back to its upright position and slide the juice tray back under the press.
Re-load the press with more pomace for another pressing, or proceed to cleaning if finished for the day.