SS-GPC13H
www.goodmanmfg.com
5
A
iRFlow
D
ATA
Model
Motor
Speed
Volts
E.S.P (In. of H
2
O)
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
GPC13
24H41**
Low
230
CFM
680
640
590
555
505
440
340
-
Watts
155
150
145
140
130
120
110
-
Med
230
CFM
895
855
815
755
700
630
545
390
Watts
230
220
215
205
195
180
170
145
High
230
CFM
1,185
1,130
1,070
1,010
930
850
760
650
Watts
350
340
325
310
295
280
265
245
GPC13
30H41**
Low
230
CFM
1,150
1,080
1,025
975
925
845
-
-
Watts
340
330
315
305
295
280
-
-
Med
230
CFM
1,335
1,275
1,205
1,135
1,075
985
910
845
Watts
425
415
400
385
370
350
330
310
High
230
CFM
1,435
1,355
1,280
1,200
1,120
1,030
950
875
Watts
485
465
455
435
415
400
385
370
GPC13
36H41**
Low
230
CFM
1,180
1,125
1,075
1,020
955
875
655
-
Watts
335
325
315
305
295
275
240
-
Med
230
CFM
1,350
1,280
1,205
1,130
1,050
985
910
845
Watts
435
420
405
385
375
350
330
310
High
230
CFM
1,450
1,370
1,290
1,205
1,130
1,040
960
885
Watts
495
480
465
440
425
400
385
370
GPC13
42H41**/
GPC13
49H41**
Low
230
CFM
1,425
1,410
1,355
1,310
1,245
1,170
1,080
-
Watts
450
445
430
420
405
390
370
-
Med
230
CFM
1,620
1,595
1,545
1,485
1,425
1,345
1,250
1,160
Watts
550
540
525
510
495
475
450
425
High
230
CFM
1,945
1,935
1,875
1,800
1,730
1,635
1,535
1,440
Watts
765
755
735
715
695
670
640
615
GPC13
48H41**
Low
230
CFM
1,425
1,410
1,355
1,310
1,245
1,170
1,080
-
Watts
450
445
430
420
405
390
370
-
Med
230
CFM
1,720
1,660
1,585
1,520
1,460
1,365
1,270
-
Watts
560
555
540
530
520
490
470
-
High
230
CFM
2,110
2,060
1,980
1,895
1,795
1,705
1,590
1,500
Watts
785
780
765
745
720
705
665
625
GPC13
60H41**
“T” 1
Low
230
CFM
1,775
1,635
1,645
1,515
1,510
1,450
1,430
1,400
Watts
395
420
435
445
455
465
470
475
“T” 2
Med
230
CFM
1,845
1,790
1,715
1,685
1,590
1,580
1,530
1,500
Watts
490
505
520
535
550
560
570
575
“T” 3
High
230
CFM
2,025
1,900
1,840
1,780
1,725
1,650
1,620
1,580
Watts
575
595
620
630
645
655
660
670
Notes
•
Data shown is dry coil; wet coil pressure drop is approximate.
•
0.1” H
2
O, for 2-row indoor coil; 0.2” H
2
O, for 3-row indoor coil; and 0.3” H
2
O, for 4-row indoor coil
• Data shown does not include filter pressure drop, approx. 0.08” H
2
O.
•
ALL MODELS SHOULD RUN NO LESS THAN 350 CFM / TON, USE HIGHER SPEED TAP OR NEXT SIZE LARGER BLOWER ASM.
See Repair Parts list.
• Reduce airflow by 2% for 208V operation.