4
CALCulate:COMPare:PERCent:UPPer
Set
Query
Description
Sets or returns the upper limit percent value for the compare
function.
Syntax
Query Syntax
CALCulate:COMPare:PERCent:UPPer <NRf>
CALCulate:COMPare:PERCent:UPPer?
Parameter
<NRf>
000.00~999.99
Return parameter
<NR2>
000.00~999.99
Example
CALC:COMP:PERC:UPP 90.00
Sets the upper limit percent value to +90.00%.
CALC:COMP:PERC:UPP?
>90.00
Returns the upper limit as +90.00%.
Note
This command is only applicable when compare mode is
set to DPER or PER for compare function.
CALCulate:COMPare:BEEPer
Set
Query
Description
Sets or returns the compare function beeper mode.
Syntax
Query Syntax
CALCulate:COMPare:BEEPer {OFF|PASS|FAIL}
CALCulate:COMPare:BEEPer?
Parameter/
Return parameter
OFF
Turns the beeper off.
PASS
The beeper will sound on a pass test
result.
FAIL
The beeper will sound on a fail test
result.
Example
CALC:COMP:BEEP FAIL
Sets the beeper on when the test result is a fail.
CALCulate:COMPare:MATH:DATa
Query
Description
Returns the deviation value for the compare function.
Query Syntax
CALCulate:COMPare:MATH:DATa?
Return parameter
<NR3>
±0.0000~9.9999E±X.