Good Will Instrument GSB-01 Quick Start Manual Download Page 8

 

 

GSB-01/GSB-02 Quick Start Guide 

8

 

Power cord for the United Kingdom 

When using the scanner box in the United Kingdom, make sure the 
power cord meets the following safety instructions. 

 

NOTE: This lead/appliance must only be wired by competent persons  

WARNING: THIS APPLIANCE MUST BE EARTHED 

IMPORTANT: The wires in this lead are coloured in accordance with the 
following code: 
Green/ Yellow: 

Earth 

 

Blue: 

Neutral 

Brown: 

Live (Phase) 

As the colours of the wires in main leads may not correspond with 
the coloured marking identified in your plug/appliance, proceed 
as follows: 
The wire which is coloured Green & Yellow must be connected to 
the Earth terminal marked with either the letter E, the earth symbol 

 or coloured Green/Green & Yellow. 

The wire which is coloured Blue must be connected to the terminal 
which is marked with the letter N or coloured Blue or Black. 
The wire which is coloured Brown must be connected to the 
terminal marked with the letter L or P or coloured Brown or Red. 
If in doubt, consult the instructions provided with the equipment 
or contact the supplier. 
This cable/appliance should be protected by a suitably rated and 
approved HBC mains fuse: refer to the rating information on the 
equipment and/or user instructions for details. As a guide, a cable 
of 0.75mm

2

 should be protected by a 3A or 5A fuse. Larger 

conductors would normally require 13A types, depending on the 
connection method used. 
Any exposed wiring from a cable, plug or connection that is 
engaged in a live socket is extremely hazardous. If a cable or plug is 
deemed hazardous, turn off the mains power and remove the cable, 
any fuses and fuse assemblies. All hazardous wiring must be 
immediately destroyed and replaced in accordance to the above 
standard. 

Summary of Contents for GSB-01

Page 1: ...lex Scanner Box GSB 01 GSB 02 QUICK START GUIDE GW INSTEK PART NO 82SB 02000M01 ISO 9001 CERTIFIED MANUFACTURER Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDep...

Page 2: ...er language without prior written consent of Good Will company The information in this manual was correct at the time of printing However Good Will continues to improve products and reserves the right...

Page 3: ...9 Firmware Note 9 Model Overview 10 Main Features 10 Accessories and Package Contents 11 Panel Overview 12 Appearance 12 GSB 01 Front Panel 12 GSB 02 Front Panel 12 GSB 01 Rear Panel 13 GSB 02 Rear P...

Page 4: ...afety symbols may appear in this manual or on the instrument WARNING Warning Identifies conditions or practices that could result in injury or loss of life CAUTION Caution Identifies conditions or pra...

Page 5: ...pening Do not disassemble the GSB 01 GSB 02 unless you are qualified Measurement categories EN 61010 1 2010 specifies the measurement categories and their requirements as follows The GSB 01 GSB 02 fal...

Page 6: ...rature 0 C 40 C Pollution Degree EN 61010 1 2010 specifies the pollution degrees and their requirements as follows The GSB 01 GSB 02 falls under degree 2 Pollution refers to addition of foreign matter...

Page 7: ...this instrument as unsorted municipal waste Please use a separate collection facility or contact the supplier from which this instrument was purchased Please make sure discarded electrical waste is p...

Page 8: ...be connected to the terminal which is marked with the letter N or coloured Blue or Black The wire which is coloured Brown must be connected to the terminal marked with the letter L or P or coloured Br...

Page 9: ...ll suited for multi point safety testing as well for volume testing on factory floors The GSB 01 has connections for ACW DCW and IR testing while the GSB 02 also includes support for GB testing Firmwa...

Page 10: ...n Features Performance 8 HV outputs 6 for GSB 02 2 GB outputs GSB 02 only ACW 5kV AC DCW 6kV DC IR 1kV DC GB 40A GSB 02 only Features PASS FAIL LEDs HI LO LEDs Up to 4 scanner boxes can be connected I...

Page 11: ...ads GHT 109 x1 GB wiring leads GSB 02 only GHT 116R x8 GSB 01 x6 GSB 02 HV test leads for scanner box outputs GHT 116B x1 Return test lead for scanner box GTL 116R x2 GB sense source H test lead GSB 0...

Page 12: ...dicators HIGH VOLTAGE Indicator POWER Button Channel Pass Fail Indicators Return Terminal GSB 02 Front Panel SOURCE H SOURCE L SENSE H SENSE L RETURN H POT R GSB 02 Mul pl x Sc nner B x GB Rx POWER H...

Page 13: ...D Line voltage input fuse GSB 02 Rear Panel HV1 HV2 OUTPUT H T X 6 5 CH3 CH4 CH6 CH5 CH7 GND ENS RE THE P WER S RE E R THE N TR ENT BEF RE REP N THE F SE 24 5 6 Hz 5 X 2 5 RS23 N RS232 OUT CH8 CH1 CH2...

Page 14: ...he scanner boxes to the safety tester When wiring the GSB 01scanner boxes to the safety tester or to each other only the HV wiring leads GHT 108 should be used Front Panel 1 Connect the High Voltage t...

Page 15: ...H HA E WER S H V A V V HV cable Return cable Safety Tester Scanner box 1 Scanner box 2 Scanner box 3 u GSB 01 T N H H H WER S H H V A V V Scanner box 4 Rear Panel 1 Connect the rear panel HV terminals...

Page 16: ...H NS RU N B R P C G H S H M S B GH O M H VO M S V B S S V V S S V S N O G ON R G H U W V S S S B S R H O R S R V D H NS U N B OR R P H US B RS232 RS232 IN HV2 HV1 Return Return RS232 OUT RS232 IN Safe...

Page 17: ...n the examples below only 3 scanner boxes are connected When wiring the GSB 02 scanner boxes to the safety tester or to each other only the GB wiring leads GHT 109 should be used Front Panel 1 Connect...

Page 18: ...x 1 Scanner box 1 Scanner box 1 SOURCE H SENSE L SENSE H Rear Panel 1 Connect the SOURCE H and SOURCE L terminals on the 1st scanner box in series to the same terminals on the 2nd and 3rd scanner box...

Page 19: ...NS U N B OR R P C NG H US H M S H B Rx S S S S S S S B GH O M S V B S S V V S S V S N O G ON R G H U W V S S B NS R H PO R S R OV D H NS U N B R R P C S B RS232 RS232 IN RS232 OUT RS232 IN RS232 OUT...

Page 20: ...only 1 Press UTILITY 1 Press EDIT SAVE to save settings or ESC to cancel and return to the previous screen 2 Press the STOP key twice for a FAIL result 3 When in MANU mode selecting MANU number 000 wi...

Page 21: ...lows you to check that all scanner boxes are properly connected to the GPT 9000 safety tester 2 A new interface setting for remote control when using the scanner boxes The Common Utility settings incl...

Page 22: ...R Example NOTE The INTERLOCK function is set to OFF by default in the Common Utility CTRL menu To increase safety set INTERLOCK to ON and use the accompanying Interlock key to enable testing If the S...

Page 23: ...be seen as configuring the output of one step of the automatic test This section will assume that you are only configuring a single manual test For automatic tests configure the scanner boxes for eac...

Page 24: ...X disable N I T I View Output Settings Press SEND so as to have the scanner box configuration displayed on the scanner displays E N D S Save Configuration To save press the EDIT SAVE key EDIT SAVE Th...

Reviews: