background image

- 1 -

Diffuser

Diffuseur

Difusor

Switch

Interrupteur

Interruptor

Model/Model/Modelo #:

UC1045-WH1-18T81-G

FLUORESCENT DIRECT WIRE UNDER CABINET BAR 

(Page 1)

LUMINAIRE FLUORESCENT À RACCORDEMENT

DIRECT À INSTALLER SOUS UNE ARMOIRE 

(Page 5)

CONEXIÓN DIRECTA DE LÁMPARA FLUORESCENTE

PARA DEBAJO DE LA BARRA DEL GABINETE 

(Página 9)

To Begin/Pour commencer/Para comenzar

Bulb

Ampoule

Bombilla

Wire Coupling

Coupleur de fils

Acoplamiento de cable

WARNING: 

Please read this entire manual before installation. 

Verify the following contents:

AVERTISSEMENT : 

Veuillez lire ce mode d'emploi du début à la fin avant

de commencer l'installation. Vérifiez le contenu suivant :

ADVERTENCIA: 

Por favor, lea este manual completo antes de realizar la

instalación. Verifique el siguiente contenido:

Hardware kit (Actual hardware may differ from illustration).

Trousse de quincaillerie (La quincaillerie incluse peut être différente de l’illustration.)

Kit de aditamentos (Los aditamentos reales pueden diferir de los que se muestran en la ilustración.)

 

  

  

Required/Nécessaire/Se necesita

Safety glasses

Lunettes de sécurité

Gafas de seguridad

Flathead screwdriver

Tournevis à tête plate

Destornillador de cabeza plana

Phillips screwdriver

Tournevis cruciforme

Destornillador Phillips

Installation time: 45 minutes

Temps d’installation : 45 minutes

Tiempo de instalación: 45 minutos

Drill bits 1/16 in.

Forets de 1/16 po

Brocas para taladro de 1/16 pulg

Electrical tape

Ruban isolant

Cinta aislante

Drill

Perceuse

Taladro
Pliers

Pinces

Pinzas

Wire cutters

Coupe-fil

Pinzas cortacables

Wire strippers

Pinces à dénuder

Pinzas pelacables      

English

Warnings and Cautions

WARNING

   

•  

Shut off power at the circuit breaker or fuse panel before removing the 

       old fixture or installing the new one.

CAUTION

 

  • 

DO NOT USE THIS FIXTURE WITH A DIMMING CIRCUIT.

 If dimmer 

       controls are present, remove them and replace them with regular 

       electrical switches. If a three-way dimmer is present, replace it with a 

       regular three-way switch. If unfamiliar with electrical installations, it is 

       recommended a qualified electrician do the installation.

  •   

This device complies with Part 15 of the FCC rules. Operation is subject 

       to the following two conditions: (1) This device may not cause harmful 

       interference, and (2) this device must accept any interference received, 

       including interference that may cause undesired operation.

Summary of Contents for UC1045-WH1-18T81-G

Page 1: ...asses Lunettesdes curit Gafasdeseguridad Flatheadscrewdriver Tournevis t teplate Destornilladordecabezaplana Phillipsscrewdriver Tourneviscruciforme DestornilladorPhillips Installationtime 45minutes T...

Page 2: ...rrow end of the keyhole slots Fig 4 5 3 Remove the bulb from the fixture by placing both thumbs on the metal ends of the bulb Fig 2 While applying slight pressure on the metal ends roll the bulb forwa...

Page 3: ...nuts properly to prevent the wires from coming loose If unsure of tightness tape the wire nuts to the wire using electrical tape Fig 12 Carefully push any excess wiring back inside the wire compartme...

Page 4: ...sumer The fixture is not warrantied for use in a commercial or retail application The warranty is limited to use in a residential environment This warranty does not cover bulbs Any applicable bulb war...

Page 5: ...celui des autres pi ces ou elle peut d j tre install e dans ses douilles Ne faites PAS fonctionner le luminaire si le collet de protection est en place Coupez le collet ou enlevez le une fois l ampoul...

Page 6: ...moyen d une perceuse Serrez les vis en prenant soin de laisser chaque vis d passer de la surface de 12 7 mm fig 5 Pour ouvrir le couvercle du compartiment des fils d gagez les deux languettes de verro...

Page 7: ...pl tement les vis bois jusqu ce qu elles ne bougent plus et que le luminaire soit solidement fix la surface de montage Replacez l ampoule dans les douilles en alignant ses broches sur les encoches des...

Page 8: ...d clairage d fectueux Le fabricant n est pas responsable des pertes des dommages des frais de main d uvre ou des blessures occasionn s par le produit Cette limite de responsabilit du fabricant inclut...

Page 9: ...O EN INTERIORES 2 No mire directamente hacia la bombilla encendida 3 La bombilla se CALIENTA Tenga cuidado al encenderla y apagarla 4 Mantenga la l mpara y la bombilla lejos de materiales que se pueda...

Page 10: ...io gu a de 1 59 mm en los lugares marcados Ajuste los tornillos dejando que 1 27 cm del tornillo sobresalga de la superficie Fig 5 Para abrir la tapa del compartimiento de los cables desenganche ambas...

Page 11: ...a aislante en los empalmes pl sticos Fig 12 Empuje cuidadosamente el exceso de cables hacia el interior del compartimiento del cable Vuelva a instalar la bombilla en el portal mpara para esto alinee l...

Page 12: ...dental o resultante III que se base en teor as de la garant a contrato negligencia responsabilidad estricta agravio o de otro tipo o IV que se relacione de manera directa o indirecta con la venta uso...